MS6(N)-SV-...-E-ASIS
Festo – MS6(N)-SV-...-E-ASIS – 1205NH English
55
Type
MS6N-SV-…-E-ASIS
MS6-SV-…-E-ASIS
Switch-through point
Approx. 50 % of p1
Fig. 7
Filling flow
adjustable through flow control valve
Fig. 8
Operating voltage range DC for
AS-interface
[V]
22.0 … 31.6
Maximum switching frequency
[Hz]
0.5
Switching time off
[ms]
40
Switching time on
[ms]
130
Duty cycle
[%]
100
Electrical connection
M12 plug
M12 socket
Protection class
IP65 with plug socket
Sound pressure level
[dB(A)]
75 with silencer UOS-1
Housing materials information
Die-cast aluminium
Seal material information
NBR
Tab. 16
General data
14.3
Switch-through pressure / filling time
With the flow control screw in the cover, a gradual pressure build-up of output pressure p2 is gener-
ated. The pressure rise can be adjusted by turning the flow control screw. Once output pressure p2
reaches approximately 50 % of operating pressure p1, the valve opens and the full operating pressure
p1 is reached at the output.
Tolerance range
t
100
%
Filling time can be adjusted
via a flow control valve
70 %
50 %
30 %
p
Switch-through point
Fig. 7
Switch-through pressure
Example:
If operating pressure p1 = 4 bar, a switch-through pressure of 1.2 … 2.8 bar is permissible, given the
maximum permissible tolerance of ±20 %.