MS6(N)-SV-...-E-ASIS
42
Festo – MS6(N)-SV-...-E-ASIS – 1205NH English
Combination with service units of the MS series
Warning
Incorrectly installing the device in the service unit combination can impair the
MS6(N)-SV-...-E-ASIS safety function.
•
Only devices that do not impair the pneumatic safety function – safe venting – may
be placed downstream of the MS6(N)-SV-...-E-ASIS.
If fitted together with one or several already present service units of the same series
Fig. 5 Assembly.
1. Remove the cover cap MS6-END
1
, if on
hand, from the side to be combined (push up-
wards).
2. Place the module connectors MS6-MV
2
in
the grooves of the individual devices. A seal is
required between the individual units (in-
cluded in the scope of delivery, module con-
nector MS6-MV or mounting bracket
MS6-WPB).
3. Fasten the module connectors MS6-MV with
2 screws.
Fig. 5
Assembly
max. 1.2 Nm
1
2
5.2
Pneumatic
5.2.1
Port 1 and 2 (thread size G
½
or NPT
½
-14)
If using screw connectors with spanner size larger than SW24:
•
Remove the cover cap MS6-END (push upwards), if on hand.
If using fittings:
•
Observe the maximum screw-in depth of the connecting threads:
ISO 228
NPT
10.0 mm
10.0 mm
Tab. 3
Max. screw-in depth