A
Technical appendix
Festo – MPAC-VI-EN – 2017-12a – English
63
Standard nominal flow rates MPA14 (size 14 mm)
Valve
Ident. code
Standard nominal flow rates [l/min] ±15 %
1
}
2 or 1
}
2
}
3/5 or 4
}
2x 2/2-way
D
720
—
2x 2/2-way
DS
570
—
2x 2/2-way
I
730
3/5
}
4:
660
3/2-way, open
W
4
}
2:
450
2
}
3: 430
3/2-way, closed
x
4
}
2: 510
2
}
3: 430
2x 3/2-way
H, N
730
640
2x 3/2-way
HS, NS
550
570
2x 3/2-way
K
760
610
2x 3/2-way
KS
600
540
5/2-way
M
720
740
5/2-way
MS
730
750
5/2-way
J
770
780
5/3-way, pressurized
B
570
5/3-way, exhausted
E
550
660 (510 ±25 %)
5/3-way, closed
G
660
670
1)
Flow direction 1
}
4 or 4
}
3/5, not with valves with ident. code I, W and X
2)
Values for the mid-position are specified in brackets.
Tab. A.6
Technical data: nominal flow rates
Valve switching times MPA14 (size 14 mm)
Valve
Ident. code
Valve switching times [ms]
±25 %
(Method of measurement 0 … 10 %
)
On/changeover
Off
2x 2/2-way
D
12
30
2x 2/2-way
I
10
28
2x 2/2-way
DS
14
25
3/2-way
W, X
12
20
2x 3/2-way
H, K, N
12
38
2x 3/2-way
HS
10
25
2x 3/2-way
KS, NS
14
25
5/2-way, monostable
M, MS
13
30
5/2-way, bistable valve
J
9/24
—
5/3-way, pressurized
B
16/26
50
5/3-way, exhausted
E
13/26
50
5/3-way, closed
G
13/26
52
Tab. A.7
Technical data: valve switching times