6
Cleaning and maintenance
Festo – MPAC-VI-EN – 2017-12a – English
47
1
2
3
1
Mounting screws of the cover
2
Mounting screws of the valve
3
Manifold sub-base
Fig. 6.1
Valve dismantling
Mounting
1. Check the seals for damage, especially the cord seals of the valve or cover plate and the IP seal of
the cover.
2. Replace seals if they are damaged.
3. Make sure that the cord seal is positioned correctly between the manifold sub-base and valve or
cover plate. The cord seal must sit in the cut-out of the valve or cover plate.
4. Insert the valve or cover plate into the manifold sub-base (
è
5. Tighten the screws for the valve or cover plate at first so they are hand-tight and then tighten firmly
(tightening torque: 0.65 Nm (±10 %)).
6. Put the IP seal and the cover onto the manifold sub-base in the right position.
7. Tighten the screws for the cover at first so they are hand-tight and and then tighten firmly with a box
spanner (tightening torque: 2.0 Nm (±10 %)).