A
Technical appendix
64
Festo – MPAC-VI-EN – 2017-12a – English
A.1.4
Electrical data
General information
Electromagnetic compatibility (EMC)
Emitted interference
Declaration of conformity
è
www.festo.com
Protection against electric shock
(Protection against direct and indirect contact
in accordance with IEC/DIN 60204-1)
Through the use of PELV circuits
(Protected Extra-Low Voltage)
1)
The valve terminal is intended for use in an industrial environment. Outside of industrial environments, e.g. in commercial and
mixed-residential areas, actions to suppress interference may have to be taken.
2)
The maximum signal cable length for the valve terminal with multi-pin plug connection is 30 m.
Tab. A.8
Electrical data: general
Valve terminal with multi-pin plug connection
Power supply
Nominal voltage (range)
[V DC]
24 (18 … 30)
Current consumption (per solenoid coil, with LED) at 24 V DC
Nominal pick-up current
[mA]
50
Pick-up duration
[ms]
20
Nominal current with current reduction
[mA]
10
Tab. A.9
Electrical data: valve terminal with multi-pin plug connection
Valve terminal with I-Port interface/IO-Link
Power supply valve terminal
Operating voltage (PS) (range)
[V DC]
24 (18 … 30)
Load voltage (PL) (range)
[V DC]
24 (18 … 30)
Residual ripple
[Vp
p
]
4
Valve terminal intrinsic current consumption at 24 V DC
Operating voltage supply U
EL/SEN
(PS)
[mA]
30
Load voltage supply U
VAL/OUT
(PL)
[mA]
30
Current consumption (per solenoid coil, with LED) at 24 V DC
Nominal pick-up current
[mA]
50
Pick-up duration
[ms]
20
Nominal current with current reduction
[mA]
10
Tab. A.10
Electrical data: valve terminal with I-Port interface/IO-Link
A.2
Accessories
è
www.festo.com/catalogue