Festo DGSL 10 Series Operating Instructions Manual Download Page 6

 Screw in two screws for attaching the effective

load:
– into the yoke plate or
– into the slide.

Fig. 5

Installation of the DGSL:
 Use centring sleeves (

è

 Accessories at www.festo.com/catalogue).

 Check whether adapter plates from the Festo multi-axis modular system are

required.

 Fasten the DGSL with the stated minimum number of screws: (

è

 table Fig. 6).

If the slide is pushed into the retracted end position, the through-holes become
accessible.

Stroke 

<

 50 mm

Stroke 

›

 50 mm

Base-surface  mount­
ing with:
– Threaded holes
– Through-holes

Minimum number of
screws

two

three

Fig. 6

Position sensing of the slide end
positions:
 Place the proximity switches in the

grooves 

9

.

On the DGSL-4, only SM

T

-10

proximity switches are permitted.

 With the DGSL-4/-8, preferably use

the lower groove on the base side.

Fig. 7

9

Rough setting of the end positions:

Note

The DGSL may be damaged if the
slide is moved without a fixed stop.
 Make sure that the slide always re­

mains in the retracted end position
when the fixed stop is dismantled.

Fig. 8

1. Move the slide into the retracted end position.
2. Unscrew the mounting screws of the fixed stop and the required cover 

aD

(

è

 Fig. 10).

A reduction of a max. 2 standard strokes is possible (for DGSL-…-E the standard
stoke range cannot be completely covered).

Stroke

0

10

20

30

40

50

80

100

150

200

Stroke reduc­
tion

1)

Fig. 9

1)

Not for DGSL-…-E

3. Replace the fixed stop 

6

 with the cover 

aD

.

4. Screw the fastening screws in again. The tightening

torque is summarised in the following table
(

è

 Fig. 11).

Fig. 10

aD

6

DGSL

4

6

8

10

12

16

20

25

Tightening torque

[Nm]

0.76

1.3

1.3

2.9

2.9

6

9

9

Fig. 11

5. Complete the precision adjustment of the end positions on the cushioning com­

ponents (

è

 6 Commissioning).

5.2 DGSL-…-N

 

without cushioning components

Note

Operating the DGSL-…-N without shock absorbers will destroy the DGSL.
 Make sure that the DGSL is operated only with cushioning.

Cushioning components for retrofitting cushioning can be ordered separately and
installed in the DGSL subsequently (

è

 10 Accessories).

Note

 Make sure that the following specifications are complied with:

– Max. permissible stop force (

è

 12 Technical data),

– Use of safeguards (e.g. cover cap 

è

 10 Accessories).

5.3 Installation, pneumatic

 Use one-way flow control valves for setting the

speed of the slide.
These are screwed directly into the compressed
air supply ports.

With size DGSL-4/-6, L-shaped restrictors on the
front of the supply port enable unhindered ac­
cess for cushioning setting (

è

 Accessories at

www.festo.com/catalogue).

Fig. 12

aA

aJ

 Remove the transport covers on the compressed

air supply ports.

 Connect the tubing to the compressed air supply

ports:

aJ

 retracting

aA

 advancing

The connecting threads must be sealed. The al­
ternative connections 

aB

 and 

aC

 to the com­

pressed air supply ports intended at the factory
are prefabricated for the DGSL. They are sealed
with blanking plugs.

Fig. 13

aA

aB

aJ

aC

5.4 Installation, electric

For position sensing with proximity switches:
 Observe the minimum distances L

1

 and L

2

between static or moving ferritic masses and the
proximity sensors (

è

 Fig. 14).

In this way you will avoid maloperation as a
result of external influences.

Fig. 14

DGSL

4

6

8

10

12

16

20

25

L1 to ferritic materials

[mm]

5

5

0

L2 to ferritic materials

15

0

Fig. 15

Summary of Contents for DGSL 10 Series

Page 1: ...ren Massen Geschwindigkeiten Nur die Einhaltung der Belastungsgrenzen erm glicht ein Betreiben des Pro dukts gem der einschl gigen Sicherheitsrichtlinien Ber cksichtigen Sie die Umgebungsbedingungen a...

Page 2: ...folgenden Tabelle zusammengefasst Fig 11 Fig 10 aD 6 DGSL 4 6 8 10 12 16 20 25 Anziehdrehmoment Nm 0 76 1 3 1 3 2 9 2 9 6 9 9 Fig 11 5 Vollziehen Sie die Feineinstellung der Endlagen an den D mpfungse...

Page 3: ...nd ggf zu korrigieren 6 2 Durchf hrung der Inbetriebnahme Vor jeder Inbetriebnahme und im Betrieb Warnung Stellen Sie sicher dass im Verfahrbereich des Antriebs niemand in die Laufrichtung der bewegte...

Page 4: ...Sie bitte das entsprechende Zubeh r aus unserem Katalog www festo com catalogue 11 St rungsbeseitigung St rung M gliche Ursache Abhilfe Ungleichf rmige Bewegung der beweglichen Masse Drossel R ckschla...

Page 5: ...those of your application e g forces torques temperatures masses speeds Operation of the product in compliance with the relevant safety regulations is contingent on adherence to the load limits Take i...

Page 6: ...0 12 16 20 25 Tightening torque Nm 0 76 1 3 1 3 2 9 2 9 6 9 9 Fig 11 5 Complete the precision adjustment of the end positions on the cushioning com ponents 6 Commissioning 5 2 DGSL N without cushionin...

Page 7: ...exact slide position must be checked during a test run with compressed air applied and if necessary corrected 6 2 Carrying out commissioning Before each commissioning and in operation Warning Make sur...

Page 8: ...sponding accessories from our catalogue www festo com catalogue 11 Troubleshooting Malfunction Possible cause Remedy Uneven movement of the moving mass One way flow control valve not installed correct...

Page 9: ...elocidades Este producto solo puede utilizarse siguiendo las directrices correspondientes de seguridad si se observan los l mites m ximos de carga Tenga en cuenta las condiciones ambientales en el lug...

Page 10: ...g 11 5 Complete el ajuste de precisi n de las posiciones finales en los elementos amor tiguadores 6 Puesta a punto 5 2 DGSL N in elementos de amortiguaci n Nota Si se pone en funcionamiento el DGSL N...

Page 11: ...imido y si es necesario debe modificarse 6 2 Ejecuci n de la puesta a punto Antes de cada puesta a punto y durante el funcionamiento Advertencia Aseg rese de que en el margen de desplazamiento del act...

Page 12: ...Accesorios Nota Seleccione el accesorio correspondiente de nuestro cat logo www festo com catalogue 11 Eliminaci n de fallos Fallo Posible causa Remedio Movimiento irregular de la masa en movimiento...

Page 13: ...s masses vitesses Seul le respect des limites de charge permet un fonctionnement du produit conforme aux directives de s curit en vigueur Tenir compte des conditions ambiantes sur le lieu d utilisatio...

Page 14: ...vant Fig 11 Fig 10 aD 6 DGSL 4 6 8 10 12 16 20 25 Couple de serrage Nm 0 76 1 3 1 3 2 9 2 9 6 9 9 Fig 11 5 Finaliser l ajustement fin des positions de fin de course sur les l ments amortisseurs 6 Mise...

Page 15: ...ion lors de la phase d essai 6 2 Ex cution de la mise en service Avant chaque mise en service et en fonctionnement Avertissement S assurer que dans la zone de d placement de l actionneur personne ne p...

Page 16: ...0 Accessoires Nota S lectionner l accessoire correspondant dans notre catalogue www festo com catalogue 11 D pannage Dysfonctionnement Cause possible Rem de Mouvement irr gulier de la masse mobile Mon...

Page 17: ...mpiego previste ad es forze momenti temperature masse velocit Solo l osservanza dei limiti di carico permette di impiegare il prodotto secondo le norme di sicurezza vigenti Tenere presente le condizio...

Page 18: ...0 12 16 20 25 Coppia di serraggio Nm 0 76 1 3 1 3 2 9 2 9 6 9 9 Fig 11 5 Microregolare le posizioni di fine corsa sugli elementi deceleratori 6 Messa in servizio 5 2 DGSL N senza elementi di ammortizz...

Page 19: ...immetten do aria compressa ed eventualmente correggerla 6 2 Esecuzione della messa in servizio Prima di ogni messa in funzione ed esercizio Avvertenza Assicurarsi che nell area di movimento dell attua...

Page 20: ...rsa 6 Messa in servizio 10 Accessori Nota Selezionare i rispettivi accessori dal nostro catalogo www festo com catalogue 11 Risoluzione dei problemi Guasto Eventuale causa Rimedio Movimento non unifor...

Page 21: ...GSL Y3 Y11 DGSL N 2 3 4 5 6 7 8 9 aJ aA aB 1 aC 1 1 Fig 1 2 DGSL 1 2 DGSL E P P1 DGSL Y3 Y11 345 DGSL 678 9 1 3 DGSL A B CD DGSL A E 7 kg 4FGH 9IJ KL M N O P Q 4 R S T UV WC IX Y Z _ L A V 3a Cb 2 c c...

Page 22: ...80 100 150 200 b J1 Fig 9 1 DGSL E 6 aD 6 7 _ Fig 11 Fig 10 aD 6 DGSL 4 6 8 10 12 16 20 25 _ Nm 0 76 1 3 1 3 2 9 2 9 6 9 9 Fig 11 8 7 6 5 2 DGSL N DGSL N DGSL T 2 DGSL DGSL 10 T V y 9 12 10 5 3 7 z 7...

Page 23: ...L Y3 DGSL Y11 1 DGSL Y11 1 DGSL Y3 _ _ Fig 21 Fig 20 DGSL 4 6 8 10 12 16 20 25 DGSL _ Nm 0 15 0 2 0 3 0 8 1 2 2 5 2 5 3 5 C DGSL Y3 _ Nm 0 5 0 8 2 2 5 8 13 DYSW Y1F 4 6 5 8 7 10 8 14 10 17 12 20 C DGS...

Page 24: ...7 z 7 z 7 b T U H 7 6 1 I 5 C DGSL Y3 9 I k 7 z4 7 z4 Fig 29 12 U VW DGSL 4 6 8 10 12 16 20 25 45 E P 5 4 P1 5 4 Y3 5 Y11 5 N ISO8573 1 2010 7 4 4 bar 2 5 8 1 5 8 1 8 M3 M5 Gx N M5 10 32 UNF x NPT U A...

Reviews: