38
Festo — CPX-AP-A — 2022-07
Technical data
12.1
Technical data, mechanical
Vibration resistance and shock resistance in accordance with EN 60068
Vibration (part 2-6)
Direct mounting SG2
H-rail SL1
Shock (part 2-27)
Direct mounting SG2
H-rail SL1
Continuous shock (part 2-27)
Direct mounting SG1
H-rail SL1
Tab. 27: Vibration resistance and shock resistance in accordance with EN 60068
Vibration load
Frequency range [Hz]
Acceleration [m/s
2
]
Deflection [mm]
Severity level 1 Severity level 2 Severity level 1 Severity level 2 Severity level 1 Severity level 2
2 … 9
2 … 9
–
–
±3.5
±
3.5
9 … 200
9 … 200
10
10
–
–
10 … 58
10 … 60
–
–
±
0.15
±
0.35
58 … 150
60 … 150
20
50
–
–
Tab. 28: Vibration load
Shock load
Acceleration [m/s
2
]
Duration [ms]
Shocks per direction
Severity level 1 Severity level 2 Severity level 1 Severity level 2 Severity level 1 Severity level 2
±
150
±
300
11
11
3
3
Tab. 29: Shock load
Continuous shock load
Acceleration [m/s
2
]
Duration [ms]
Shocks per direction
Severity level 1
Severity level 1
Severity level 1
±
150
6
1000
Tab. 30: Continuous shock load