5. Analogue output module CPX−2AA−U−I
5−39
Festo P.BE−CPX−AX−EN en 0503b
5.5.3
Fault treatment and parametrizing
The following diagrams show the fault treatment in the ana
logue output modules. Further registering and display of the
fault can be suppressed as desired with the appropriate mod
ule parameter, represented in the diagram as a switch. A de
scription of the parameter can be found in section 5.4.3.
2
Fault message to
field bus node
Module
error LED
1
Fault no. 15
Module
defective
Monitoring
Short circuit
at outputs
0
1
Fault no. 26
Fault in
actuator supply
1
Module parameters
(switch position represented = default setting)
2
Module−specific faults
3
Channel−specific faults
Fig.5/9:
Principle of fault treatment and parametrizing of
the analogue output modules part 1
Summary of Contents for CPX-2AA-U-I
Page 2: ......
Page 19: ...Overview and connection technology I O modules 1 1 Festo P BE CPX AX EN en 0503b Chapter 1...
Page 44: ...1 Overview and connection technology I O modules 1 26 Festo P BE CPX AX EN en 0503b...
Page 45: ...Analogue input module CPX 2AE U I 2 1 Festo P BE CPX AX EN en 0503b Chapter 2...
Page 83: ...Analogue input module CPX 4AE I 3 1 Festo P BE CPX AX EN en 0503b Chapter 3...
Page 122: ...3 Analogue input module CPX 4AE I 3 40 Festo P BE CPX AX EN en 0503b...
Page 123: ...Analogue input module CPX 4AE T 4 1 Festo P BE CPX AX EN en 0503b Chapter 4...
Page 157: ...Analogue output module CPX 2AA U I 5 1 Festo P BE CPX AX EN en 0503b Chapter 5...
Page 198: ...5 Analogue output module CPX 2AA U I 5 42 Festo P BE CPX AX EN en 0503b...
Page 199: ...Technical appendix A 1 Festo P BE CPX AX EN en 0503b Appendix A...
Page 221: ...Index B 1 Festo P BE CPX AX EN en 0503b Appendix B...
Page 222: ...B Index B 2 Festo P BE CPX AX EN en 0503b Contents B Index B 1...