8. Service functions and error messages
112
Festo.P.BE-CMMS-ST-HW-EN 0903b
Error message
Meaning of error
message
Measures
Error
reaction
Main
index
Sub-
index
64
0
DeviceNet initialisation
error
PS off
1)
1
DeviceNet assembly error
PS off
1)
2
DeviceNet
communication error
Common fault
PS off
1)
3
DeviceNet
communication error
Common fault
PS off
1)
4
DeviceNet
communication error
Common fault
PS off
1)
5
DeviceNet
communication error
Common fault
PS off
1)
6
DeviceNet
communication error
Common fault
PS off
1)
65
0
DeviceNet assembly error
PS off
1)
1
DeviceNet
communication error
Common fault
PS off
1)
70
2
General arithmetic error
The FHPP factor group cannot be calculated
correctly.
PS off
3
Fault in operating mode
Change of operating mode with enabled end
stage.
PS off
1)
79
0
RS232 communication
fault
Common fault
PS off
1)
1)
PS off:
Qstop:
Warn:
Ignore:
Changeable with FCT
Switch off power section
Fast stop
Warning
Ignore
Tab. 8.2: Error messages
Error messages can be acknowledged with:
-
the parameterizing interface,
-
via the field bus (control word),
-
a falling edge at DIN5 (controller enable).