![Festo CMMS-ST-C8-7 Assembly And Installation Manual Download Page 30](http://html1.mh-extra.com/html/festo/cmms-st-c8-7/cmms-st-c8-7_assembly-and-installation-manual_2283132030.webp)
3. Product description
30
Festo.P.BE-CMMS-ST-HW-EN 0903b
I/O timing diagrams
ENABLE
START
STOP
Drive is moving
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
DOUT0: READY
DOUT1: MC
DOUT3: ERROR
DOUT2:
Speed
reached
t1
t1
tx
tx
t
mc
t1
= 1.6 ms
tx
= x ms (dependent on ramps)
tmc
= x ms (dependent on MC window)
Fig. 3.1: Signal sequence with Synchronization selection operation mode /
with activation of synchronization through START (DIN8)
Note
Starting with Firmware 1.3.0.1.7, the message "Position synchro-
nized" is output at DOUT2.
The signal MC is set as long as the drive is at standstill with active synchronization
(DIN8: START set). That is, the MC signal is set as long as the window for "DZ = 0
recognised" has not been left.