3. Technical specificationsProduct description
Festo.P.BE-CMMS-ST-HW-EN 0903b
25
3.3.3
Analogue setpoint specification
The analogue setpoint specification ±10 VDC can be configured as setpoint specification
for
-
Speed setpoint value
-
Torque setpoint value
Required connection with analogue setpoint specification
The connection plan shows the switch position in the active operating state.
*) The limit switches are set by default to opener (configuration over FCT)
3.3.4
Interfaces for direct synchronous operation
The motor controller permits a master-slave mode, which hereafter is designated
synchronization. The controller can function either as a master or slave.
If the motor controller works as master, it can provide (RS422) A/B signals to the
incremental encoder output (X10).
When the motor controller is to operate as a slave, various inputs and signal forms are
available for synchronization.
X10
[5V RS422]: A/B, CW/CCW, CLK/DIR
X1
[24V]:
CW/CCW, CLK/DIR