![Festo CMMS-ST-C8-7 Assembly And Installation Manual Download Page 54](http://html1.mh-extra.com/html/festo/cmms-st-c8-7/cmms-st-c8-7_assembly-and-installation-manual_2283132054.webp)
3. Product description
54
Festo.P.BE-CMMS-ST-HW-EN 0903b
Homing -
method
-18
Positive stop
Run at search speed in positive direction to stop. This position is saved as a reference
point.
If configured: Run at travel speed to axis zero point.
33
Index pulse in a negative direction
Run at crawl speed in negative direction to index pulse. This position is saved as a
reference point.
If configured: Run at travel speed to axis zero point.
34
Index pulse in a negative direction
Run at crawl speed in positive direction to index pulse. This position is saved as a
reference point.
If configured: Run at travel speed to axis zero point.
35
Current position
The current position is saved as the reference point.
If configured: Run at travel speed to axis zero point.
Note: If the reference system is shifted, runs to the limit switch or fixed stop are possible.
The are therefore generally used for rotating axes.
Tab. 3.19: Explanation of the homing methods