![Festo CDSA-D3-RV Operating Instructions Manual Download Page 47](http://html1.mh-extra.com/html/festo/cdsa-d3-rv/cdsa-d3-rv_operating-instructions-manual_2284182047.webp)
Mounting instructions
1 Detailed view of the mounting
2 Control cabinet wall
Fig. 27 Dimensional drawing of the mounting opening for the interface housing CAMI-C
Technical data of the interface housing
General information
Nominal voltage (CDSA-D3-RV)
[V DC]
24
Nominal voltage tolerance range
(CDSA-D3-RV, in accordance with
EN 61131-2)
[V DC]
19.2
…
30
Max. interruption duration of the supply
voltage (CDSA-D3-RV, corresponding to
EN 61131)
[ms]
£
10
Power consumption
–
Without CDSA-D3-RV
None
–
With CDSA-D3-RV
è
Tab. 21 Technical data, general
Starting current (CDSA-D3-RV)
è
Technical data of the handheld terminal
Technical data
47
Festo — CDSA-D3-RV — 2020-08