13.1.3
Regulations
Regulation
Title
Regulation (EC) Nr. 1907/2006
REACH EU Chemicals Regulation
Tab. 18 Regulations
13.2
Handheld terminal CDSA-D3-RV
Emergency stop device
Nominal voltage (U
e
)
[V DC]
24
Minimum current (I
e
)
[mA]
10 (per contact)
Max. current rating
[mA]
1,000 (per contact)
Utilisation category (in accordance with
IEC 60947-5-1)
DC-13
Schlegel FRVKOO
–
B
10D
250,000
Design
two-circuit, external wiring
Electrical isolation
[V AC]
500 to all other networks
Tab. 19 Emergency stop device
3-position enabling switch
Output type
Electromechanical switching contact
Switchable nominal voltage (U
e
)
[V DC]
24
Nominal voltage tolerance range (in accord-
ance with EN 61131-2)
[V DC]
19.2
…
30
Max. nominal current (I
e
)
[mA]
500
B
10D
–
Switch setting 2
10
6
–
Switch setting 3
10
6
Actuating forces
–
From switch position 1 to 2
Typically 3 N
–
From switch position 2 to 3
Typically 17 N
Electrical isolation
[V AC]
500 to all other networks
Tab. 20 3-position enabling switch
Technical data
40
Festo — CDSA-D3-RV — 2020-08