Specifications

Load capacity

496

 lbs

225

 kg

Weight*

11

 lbs

5

 kg

Materials

Structure

Aluminium

Load capacity

Inspect the device to check 

that its load capacity has 

not been exceeded (see the 

section on 

Inspection)

.

496 lb

225 kg

Initial setup of the Light Mule

Before using the Titan-T stretcher with the carrying 

handles:

● 

Apply the handle fixing system on the stretcher 

Titan-T, and this will remain fixed even without use 

of the handles.

● 

Assemble the handles making sure that the fixing 

system is engaged.

● 

Inspect the stretcher (see the section on Inspection).

● 

Double check that all the straps are in place prior to 

transport

 

WARNING

Incorrect use of the device can result in damage 

and/or injury. Use the device as instructed in this 

manual.

Configuration

The Light Mule transport system was designed to make it 

easier and safer for operators to transport the patient in a 

SAR environment

1. 

Make sure that all the mechanisms are fitted correctly

2. 

Mount the supports on the upper tube, checking the 

quick release system

3. 

Fit the transport wheel, checking that the locking pin 

is fully in place

4. 

Adjust the position of the handle as required

Summary of Contents for Tirol Kit

Page 1: ...User and maintenance manual Titan T Basket stretcher and Tirol Kit Rel 170915 English Readthismanual carefullyandkeepit forfuturereference...

Page 2: ...quired level of safety to prevent injury to operators and patients Any other safety measure implemented by the user must comply with local regulations It is recommended to train staff in proper use of...

Page 3: ...nance can cause serious accidents injuries and or damage Perform maintenance as instructed in this user manual The use of improper and unauthorised devices can cause accidents damage and or injury Use...

Page 4: ...nt The device must be used by trained and qualified personnel and for professional use only by a minimum of two qualified operators More operators may be required depending on local protocols Addition...

Page 5: ...oad capacity Quick Release System Strap Rigid surface for the management of trauma and CPR Quick release straps Mule Single wheel transport system Handles for Titan Light Mule Light Mule Ultra light o...

Page 6: ...them during purchase Titan Ti 11 0118 and 11 0118SL 211 X 58 X 18 cm Titan Ti Split Apart 11 0119 and 11 0119SL 211 X 60 X 18 cm Maximum capacity 11 3 KN 1134 Kg Weight of Titan Ti 11 0118 6 1 Kg Weig...

Page 7: ...the free end of the strap to settle the three pin buckle evenly on the two pin buckle Fig 3 7 Tighten the strap by pulling on the free end of the strap 8 Loosen and open the straps 9 To loosen the str...

Page 8: ...ructions and local health protocols Always assist the patient and never leave the patient alone during operations involving the stretcher Always use the original straps to secure the patient to the st...

Page 9: ...er During rescue operations in a vertical environment the stretcher can be held horizontally vertically or in other positions Secure the patient on the stretcher so that the patient cannot slip in any...

Page 10: ...the patient Use of the stretcher in a safe environment The operators must lift and carry the stretcher accepting any assistance to help them avoid obstacles or difficult terrain Before lifting the str...

Page 11: ...tion Lubrication Adjusting the tightness Routine and preventive maintenance The stretcher is a medical device requiring regular maintenance hence you are recommended to comply with the following sched...

Page 12: ...Tirol Kit Light Mule components Handles Wheel locking system Trauma management support yellow Adjustable carrying handles Straps Arm support Transport wheel Quick release system Quick release system...

Page 13: ...TA Titan T Basket stretcher and Tirol Kit Locking system to be applied on the Titan stretcher Adjustable carrying handles Wheel locking system Arm support Transport wheel Handles for Titan Light Mule...

Page 14: ...ure the safety of the patient and that of themselves This manual explains the use of the stretcher in an ideal situation and is purely indicative The device must be used by two or more operators who a...

Page 15: ...t the side of each handle Installation of the adjustable carrying handles After mounting the Titan T stretcher with the handle adjustment system place the stretcher on the ground and with the assistan...

Page 16: ...ve the same purpose but have a different fastening system Adjustable handles for stabilising on the ground SS Shoulder Support transport harness Disinfection Cleaning the straps 1 Remove the straps fr...

Page 17: ...the carrying handles Apply the handle fixing system on the stretcher Titan T and this will remain fixed even without use of the handles Assemble the handles making sure that the fixing system is engag...

Page 18: ...to the section on Additional assistance Always observe the instructions and local health protocols Always assist the patient and never leave the patient alone during operations involving the stretcher...

Page 19: ...the support arms have been mounted and checked an operator can lift the stretcher with or without the aid of the carrying handles to facilitate assembly 2 The supports are positioned under the stretch...

Page 20: ...and Tirol Kit Mount the wheel axle with the threaded insert using both holes After inserting the wheel axle screw it on to the end of the thread At the end of thread fully tighten the locking lever an...

Page 21: ...good condition and to remove all traces dirt debris and bodily fluids The devices must be inspected before and after each use and cleaned after each use If the devices are not used they must be stored...

Page 22: ...tient and that of themselves The device must be used by trained and qualified operators Ferno recommends the presence of a supervisor during the use of the garrison in the SAR environments Remove wate...

Page 23: ...at low temperature with detergent and use a gentle cycle Do not use bleach or other bleaching agents 5 Remove the system from the bag and leave it out to dry Do not put in a tumble dryer Stable mounti...

Page 24: ...surface finishes gelcoat resin paint powder paint decals ribbons writing etc are guaranteed for 90 days Repairs are performed by trained technical staff at the site of Washington Ferno Italia s r l in...

Page 25: ...the event that the product is used not in compliance with the instructions or for purposes other than those for which it was designed As indicated in the Warranty Conditions Ferno Washington Italia s...

Page 26: ...26 Ferno Washington Italia Rel 170915 ITA Titan T Basket stretcher and Tirol Kit TRAINING RECORD Date Name of Instructor Type of Training...

Page 27: ...27 Ferno Washington Italia Rel 170915 ITA Titan T Basket stretcher and Tirol Kit MAINTENANCE RECORD Date Type of Maintenance MaintenanceTechnician...

Page 28: ...ne 26 40066 Pieve di Cento BO ITALY Telephone toll free 800 501 711 Phone 39 0516860028 Fax 39 0516861508 Email info ferno it Website www ferno it User and maintenance manual of the product required t...

Reviews: