11
KIN PANEL
2.6. LIFT
2.5. FACE RECOGNITION
Use this setting to enable or disable the FACE
RECOGNITION
function of the panel.
The FERMAX MANAGEMENT
SOFTWARE
V01.05 is required for programming and managing the photos of
the authorized faces if the model is 5.0.
The FERMAX MANAGEMENT SOFTWARE V01.06 is required for programming and managing the photos of
the authorized faces if the model is 6.0.
FACE RECOGNITION:
Enable or disabled face recognition function.
AUTO ACTIVATION:
Enable or disable auto activation function of QR code or face recognition. If enabled,
wait 15 seconds for any process to end.
MODEL:
5.0, 6.0 options. Default 6.0.
The FERMAX MANAGEMENT SOFTWARE V01.05 is required for programming and managing the photos of
the authorized faces if the model is 5.0.
The FERMAX MANAGEMENT SOFTWARE V01.06 is required for programming and managing the photos of
the authorized faces if the model is 6.0.
LIVENESS DETECTION:
Enable or disabled LIVENESS DETECTION function.
SIMILARITY:
High, medium and low options. Default is low.
NOTES:
MEET panel face recognition function is based on a bidimensional face identification, with the ability of
differentiating among photos or live faces in certain conditions.
This technology can be used to open doors but cannot guarantee the highest security level or 100% accuracy
of liveness detection.
The block panel will show lift dispatch if the LIFT function is enabled.
LIFT DISPATCH
:
Enable or disable LIFT DISPATCH function.
WAITING TIME
:
This time will define the maximum time that the message “Please wait for lift dispatch” will
be shown on the display.
The WAITING TIME need be extended based on the delay time of receiving the signal from the elevator to
the MEET 32 input module. If the signal is not received within this time on the MEET 32 input module,then the
“Please wait for lift dispatch” information on the panel will disappear and a message of “Lift dispatch failed”
will be displayed.
NUMBER OF INPUT PORTS
:
Only available in panel programmed as PANEL 1. according to quantity of lift
and block panel , then select number of input ports.