TS2000 PRINTERS OPERATION MANUAL
4.7.
DIGITAL OUTPUT
The TS2000 has an optional digital output which can be used for different purposes such a blink
and external warning light when a ticket has not been picked up or the printer is running out of paper,
activate a beeper when previous or other events are triggered, etc.
Fig.4.12.
Digital output pin-out.
The digital output can be triggered either by any of the error events or can be activated
instantaneously using the same command:
DC3 p m ton toff
.
The digital output provides a signal that can blink or stay stable for up to 16 cycles. In case that a
blinking output is preferred, the time the output stays on and off are also programmable.
Fig.4.13.
Digital output examples.
The transistor's output capability is: Vco = 45V , I
C
= 100mA. Values beyond this absolute
maximum ratings could result in a permanent damage of the device.
17/58