Fema Smart DCM Operating Instructions Manual Download Page 18

SMART SN TRANSMITTER – BEDIENUNGSANLEITUNG 

MU2B-0328GE51 R0207A 

18

SN TRANSMITTER 

MENÜNAVIGATION 

 

MODE

FUNCTION

OUTPUT

START-PT

END-PT

AUTO-0

SET ZERO

RESET 0

PRESSURE,

STATE

START-PT.

WELCOME

END-PT.

MODE

FUNCTION ATTENUATION

MESSAGE

MESSAGE

ATTENUATION

PEAKS

UNIT

LANGUAGE

BACKLIGHT

REFRESH

ROTATE

CONTRAST

DISPLAY

CLEAR

MIN.

MAX. TEMP.

SIMUL.

SET CODE

RESET

EXTRAS

ENTER

CODE

GO TO

CONFIRM

ALL

SETTINGS

PLAUSIBLE

?

NO

YES

START-PT.

END-PT.

MODE

FUNCTION ATTENUATION

CODE

SIMUL.

STORING...

DISPLAY LEVEL

PARAMETRIZATION LEVEL

CODE

ERROR

START

CONFIRMATION LEVEL

 

Abb. 9. Menünavigation - Übersicht (SN) 

 
Geräte, die mit einem HMI-Kopf ausgestattet sind, verein-
fachen die Konfiguration mit Hilfe der Drucktasten und einer 
Anzeige. Die am Rande angezeigten Begriffe und Symbole 
erleichtern die Navigation durchs Menü. 
Das Menü läßt sich in folgende Bereiche aufteilen: 

 STARTANZEIGE; 

  DISPLAY-BEREICH (Informationsanzeige einschließlich 

des aktuellen Drucks, sowie verschiedener Einstellwerte. 
Editieren ist hier nicht möglich); 

  CODE-BEREICH (Eingabe des vierstelligen CODEs, um 

in die nächste Ebene zu gelangen); 

 PARAMETRISIERUNGSBEREICH 

(Änderung 

verschiedener Einstellwerte); 

  PRÜFBEREICH (Überprüfung auf korrekte Eingabe und 

ggfls. Zurückstufung in den PARAMETRISIERUNGS-
BEREICH); und 

  BESTÄTIGUNGSBEREICH (Nochmalige Bestätigung der 

Einstellwerte, bevor sie dauerhaft gespeichert werden). 

 

STARTANZEIGE 

Binnen 10 Sekunden nach Einschalten des Geräts erscheint 
als erstes die STARTANZEIGE (siehe Abb. 10). 
 

Startup

 

Abb. 10. Startanzeige 

Danach gelangen Sie automatisch in den DISPLAY-
BEREICH. 

DISPLAYBEREICH 

Im DISPLAYBEREICH können Sie den aktuellen Druck sowie 
diverse andere Einstellwerte sehen. 
 

Function

Att. filter

Non-inv.

10%

MENU

N

EXT

PR
EVI
OU
S

End

pressure

10.00bar

Mode

2-wire

4..20mA

Start

pressure

0.00bar

MENU

N

EXT

PR
EVI
OU
S

ESCAPE

ESCAPE

MENU

N

EXT

PR
EVI
OU
S

ESCAPE

N

EXT

PR
EVI
OU
S

ESCAPE

MENU

N

EXT

PR
EVI
OU
S

ESCAPE

MENU

0.22

bar

4.35mA

MENU

N

EXT

PR
EVI
OU
S

 

Abb. 11. DISPLAYBEREICH (Beispiel: SN 2-Leiter) 

 

Function

Att. filter

Non-inv.

10%

MENU

N

EXT

PR
EVI
OU
S

End

pressure

10.00bar

Mode

3-wire

0..10V

Start

pressure

0.00bar

MENU

N

EXT

PR
EVI
OU
S

ESCAPE

ESCAPE

0.22

bar

0.21V

MENU

N

EXT

PR
EVI
OU
S

MENU

N

EXT

PR
EVI
OU
S

ESCAPE

N

EXT

PR
EVI
OU
S

ESCAPE

MENU

N

EXT

PR
EVI
OU
S

ESCAPE

MENU

 

Abb. 12. DISPLAYBEREICH (Beispiel: SN 3-Leiter) 

EINGABE DES ZUGANGSCODES 

Um in den PARAMETRISIERUNGSBEREICH zu gelangen 
und dort Einstellwerte ändern zu können, müssen Sie sich 
zuerst mit der erforderlichen Autorisierung ausweisen. Dies 
geschieht durch Eingabe des vierstelligen ZUGANGSCODEs 
(Standardwert: 0000). 
 

Summary of Contents for Smart DCM

Page 1: ...0 95 r h non condensing Temperature of medium 30 100 C 16 bar models 40 100 C 16 bar models Storage temperature Versions non HMI 40 80 C 16 bar 40 100 C 16 bar Versions HMI 30 80 C Climate class Indo...

Page 2: ...here the device will check the plausibility of your values and if necessary redirect you back to the PARAMETRIZATION LEVEL and The CONFIRMATION LEVEL where you can review your edited values before per...

Page 3: ...to local ambient atmospheric pressure and to compensate for drift To use this function properly the device must be mounted in the application and the pressure sensor exposed to local ambient atmosphe...

Page 4: ...e simulation mode is started No The device remains in its normal operating mode The default setting is No WARNING After you have completed testing in the simulation mode do not forget to return to thi...

Page 5: ...250 mA the load is disconnected and the WARN output is set to 0 5 V in a loop Table 2 DCM Switch functions and definitions definition function equa tion active inactive max monitor N O 1 closed open m...

Page 6: ...ausibility of your values and if necessary redirect you back to the PARAMETRIZATION LEVEL and The CONFIRMATION LEVEL where you can review your edited values before permanently storing them START SCREE...

Page 7: ...2 Wire Trans mitter is 4 20 mA However it can be inverted to 20 4 mA see section Function below FUNCTION Here you can invert the device s function see also Fig 15 Non invert the mode current range or...

Page 8: ...e contrast is increased to its maximum value The default setting is Mean EXTRAS SIMUL SIMULATION MODE The simulation mode allows the user to test the device within the application without actually app...

Page 9: ...passive 0 mA 3 Wire 0 10 V passive 0 V The output limits of the device s outputs at overpressure and underpressure are as follows Table 4 SN Transmitter output limits at over underpressure device out...

Page 10: ...er The Y axis displays the generated output in the range according to the output definition see Fig 15 on page 7 and Table 5 on page 9 DCM SWITCH Measuring pressures is the safety function of the dire...

Page 11: ...output pin 2 If due to miswiring or electronic failure the signal output cannot reach the desired high failure state it will auto matically go to the low failure state Table 6 SN Transmitter error rep...

Page 12: ...ontact FEMA 6 Device memory check failure R U Hardware reset as described above Contact FEMA 7 Device program flow failure R U If unrecoverable Contact FEMA 8 Environment too hot or electronics failur...

Page 13: ...sionen mit HMI 20 70 C Rel Luftfeuchtigkeit 0 95 nicht kondensierend Mediumtemperatur 30 100 C 16 bar Modelle 40 100 C 16 bar Modelle Lagertemperatur Versionen ohne HMI 40 80 C 16 bar 40 100 C 16 bar...

Page 14: ...ener Einstellwerte PR FBEREICH berpr fung auf korrekte Eingabe und ggfls Zur ckstufung in den PARAMETRISIERUNGS BEREICH und BEST TIGUNGSBEREICH Nochmalige Best tigung der Einstellwerte bevor sie dauer...

Page 15: ...st N O AUTO ZERO Die auto zero Funktion erm glicht es dem Anwender das Ger t entsprechend den lokalen atmosph rischen Druck verh ltnissen einzustellen sowie die Drift auszugleichen Um diese Funktion r...

Page 16: ...das Ger t wieder in Sicherheitsanwendungen eingesetzt werden Yes Der Simulationsmodus wird aufgerufen No Das Ger t bleibt in seiner normalen Betriebsart Die Werkseinstellung ist No VORSICHT Nach Absc...

Page 17: ...annungsversorgung gestellt Falls der Strom immer noch h her als 250 mA ist wird die Last getrennt und der WARN Ausgang auf 0 5 V in eine Schleife gestellt Tabelle 2 DCM Funktionen und Definitionen Def...

Page 18: ...ung auf korrekte Eingabe und ggfls Zur ckstufung in den PARAMETRISIERUNGS BEREICH und BEST TIGUNGSBEREICH Nochmalige Best tigung der Einstellwerte bevor sie dauerhaft gespeichert werden STARTANZEIGE B...

Page 19: ...tiert werden siehe Abschnitt Function Funktion unten FUNCTION FUNKTION Hier k nnen Sie die Ger tefunktion invertieren siehe auch Abb 15 Non invert der Modus Strom bzw Spannungsbereich wird auf 0 4 20...

Page 20: ...Simulationsmodus erm glicht es dem Anwender die reibungslose Funktion des Ger ts zu pr fen ohne das System unter Druck zu setzen Nach Aufrufen des Simulationsmodus sind die Diagnostik funktionen nicht...

Page 21: ...V passiv 0 V Die Ausgangsgrenzen der Ger teausg nge bei ber und Unterdruck sind wie folgt Tabelle 4 SN Transmitter Ausgangsgrenzen bei ber und Unterdruck Ger t Ausgangs signal bereich min Ausgangs gre...

Page 22: ...te besteht darin Dr cke zu messen Je nach dem wie das Ger t eingestellt ist l t es sich mit einer Genauigkeit von 5 als Max Min oder Window W chter Schalter ausgang und WARN Ausgang betreiben Wenn di...

Page 23: ...er automatisch in den niedrigen Fehlerzustand fallen Tabelle 6 SN Transmitter Fehlermeldung Fehlermeldung Modell Aus gangs signal Bereich prim rer hoher Fehler zustand sekund rer niedriger Fehler zust...

Page 24: ...ntaktieren 6 Speicherpr fung fehlgeschlagen B NB Wie oben beschrieben Hardware Reset durchf hren FEMA kontaktieren 7 Programmlauffehler B NB Falls nichtbehebbar FEMA kontaktieren 8 Umgebung zu hei ode...

Reviews: