FEMA ELECTRÓNICA . Series K . K40-C1

21

This instrument has been designed and verified conforming to the 61010-1 
CE Security Regulation, for industrial applications.
Installation  of  this  instrument  must  be  performed  by  qualified  personnel 
only. This manual contains the appropriate information for the installation. 
Using the instrument in ways not specified by the manufacturer may lead to 
a reduction of the specified protection level. Disconnect the instrument from 
power before starting any maintenance and / or installation action.
The instrument does not have a general switch and will start operation as 

1.24 

Precautions on installation

Risk of electrical shock. Instrument terminals can be connected 
to dangerous voltage.

Instrument protected with double isolation. No earth connection 
required.

Instrument conforms to CE rules and regulations. 

Manufacturer  FEMA ELECTRÓNICA, S.A. 
 

Altimira 14 - Pol. Ind. Santiga 

 

E08210 - Barberà del Vallès  

 

BARCELONA  - SPAIN 

 

www.fema.es - [email protected]

Products  

K40-C1

The manufacturer declares that the instruments indicated comply with the 
directives and rules indicated below.
Directive of electromagnetic compatibility 2004/108/CEE 
Directive of low voltage 73/23/CEE

Security rules 61010-1

Instrument  

Fixed 

 

Permanently connected 

Pollution degree 1 and 2 (without condensation)  
Isolation  

Double 

Emission rules

61000-6-4  

Generic rules of emission

Immunity rules

61000-6-2 

Generic rules of immunity

61000-4-2 

By contact ±4 KV - Criteria B 

 

By air ±8 KV - Criteria B

61000-4-3  

Criteria A

61000-4-4  

On AC power lines : ±2 KV - Criteria B 

 

On DC power lines : ±2 KV - Criteria B 

 

On signal lines : ±1 KV - Criteria B

61000-4-5 

Between AC lines ±1 KV - Criteria B 

 

Between DC lines ±0.5 KV - Criteria B 

61000-4-6 

Criteria A

61000-4-8 

30 A/m a 50 Hz - Criteria A

61000-4-11 

0 % 1 cycle - Criteria A 

 

40 % 10 cycles - Criteria A 

 

70 % 25 cycles - Criteria B 

 

0 % 250 cycles - Criteria B

Barberà del Vallès May  2014 
Daniel Juncà - Quality Manager

1.25 Warranty

1.26 

CE declaration of conformity

This instrument is warranted against all manufacturing defects for a 
period of 24 MONTHS from the shipment date. This warranty does 
not apply in case of misuse, accident or manipulation by non-autho-
rized personnel. In case of malfunction get in contact with your local 
provider to arrange for repair. Within the warranty period and after 
examination by the manufacturer, the unit will be repaired or substi-
tuted when found to be defective. The scope of this warranty is lim-
ited to the repair cost of the instrument, not being the manufacturer 
eligible for responsibility on additional damages or costs.

soon as power is connected. The instrument does not have protection fuse, 
the fuse must be added during installation.
The instrument is designed to be panel mounted. An appropriate ventilation 
of the instrument must be assured. Do not expose the instrument to excess 
of humidity. Maintain clean by using a humid rag and do NOT use abrasive 
products such as alcohols, solvents, etc.
General recommendations for electrical installations apply, and for proper 
functionality  we  recommend  :  if  possible,  install  the  instrument  far  from 
electrical noise or magnetic field generators such as power relays, electrical 
motors, speed variators, ... If possible, do not install along the same conduits 
power cables (power, motor controllers, electrovalves, ...) together with sig-
nal and/or control cables.
Before  proceeding  to  the  power  connection,  verify  that  the  voltage  level 
available matches the power levels indicated in the label on the instrument.
In  case  of  fire,  disconnect  the  instrument  from  the  power  line,  fire  alarm 
according to local rules, disconnect the air conditioning, attack fire with car-
bonic snow, never with water.

Summary of Contents for K Series

Page 1: ...N Reading with 4 digit display Fast access to alarm setpoints special modes for fast counting and for slow ratemeter applications on power up function configurable reading brightness Universal AC and...

Page 2: ...enu see section 1 19 10 Function Trigger Sense helps to detect the correct trigger level see section 1 13 Multiple display filters memory for maximum and minimum reading password protection 5 brightne...

Page 3: ...scalable read ing The quadrature ratemeter mode has 2 inpur channels available for detection of sense of turn when working with quadrature signals Scalable reading with configurable multiplier factor...

Page 4: ...the SnSr menu entry will configure the sen sor parameters to the values indicated in the table The table also indicates the typical con nections for each type of sensor Param ters can be manually modi...

Page 5: ...nal see section 3 2 Output and control options relays analog outputs serial communi cations see section 2 Mechanical mounting panel connections plug in screw terminal housing material ABS polycarbonat...

Page 6: ...nstrument restart power up or configuration change is used for internal initialization and will not be counted as impulse 1 15 SLOW mode 1 13 Function Trigger Sense The trigger level is automatically...

Page 7: ...ENTER key It selects and accesses the menu option currently dis played At menus with numerical value entries it validates the num ber displayed Key UP 5 the UP 5 key gives access to the fast access me...

Page 8: ...e Impulses input at channel A Channel B disabled Access the Decimal point dP menu to select the decimal point position Move the decimal point by pressing the LE 3 key Configure the function mode selec...

Page 9: ...when channel B is at logical state 1 Select on_0 to inhibit the counting when channel B is at logical state 0 1 19 4 Configuration for cnI 3 Configuration menu for mode counter control add substract c...

Page 10: ...vate the SLoW mode and assign the Maximum waiting time between 1 and 1000 seconds See section 1 15 for more information on the SLoW mode in case of unstable signals activate the average filter AVr fun...

Page 11: ...ture cycle Select 1 4 for 4 impulses per quadra ture cycle for slow frequencies activate the SLoW mode and assign the Maximum waiting time between 1 and 1000 seconds See section 1 15 for more informat...

Page 12: ...channel Act r configures the activa tion of the reset channel by rising edge on_h or by falling edge on_0 Excitation voltage V EXc configures the value of the excita tion voltage at 5Vdc 9Vdc 15Vdc an...

Page 13: ...vation delay dEL 1 configure the delay to apply before alarm deactivation The deactivation delay starts counting when the setpoint value plus the hysteresis value is passed Value from 0 0 to 99 9 seco...

Page 14: ...cess to a list of functions configurable by the operator See section 1 17 for an ex planation on how to operate the fast access menu The Key UP Fast access K uP menu allows to select which func tions...

Page 15: ...1 19 20 Firmware version 1 19 21 Brightness The Counter overrange c orG and Counter underrange c urG parameters configure the behavior of the instrument when reading is higher than 9999 overrange or...

Page 16: ...ounter inhibition Multiplier Divider Preset Preset value 1999 to 9999 Mode Up Down Inhibition Inhibits if chan nel B is high Inhibits if chan nel B is 0Vdc Multiplier 1 to 9999 Divider 1 to 9999 Confi...

Page 17: ...atic conf Edges 1 imp per cycle 2 imp per cycle 4 imp per cycle Average filter SLOW mode Max waiting time 1 to 1000 Sec Filter strength by rising edge by falling edge Activation for channel A Trigger...

Page 18: ...s Setpoint2 Active Alarm type Alarms Activation delay Deactivation delay Relay inverted Locked alarm Tools Key UP fast access Memory of maximum Memory of minimum Setpoint1 Setpoint2 Setpoint3 Memory o...

Page 19: ...5Vdc Activation for channel A on rising edge on_h Excitation voltage 5Vdc Antirrebound filter 0mSeconds Tools Fast access Key UP off On Power Up Delay 0seconds Key LE reset function Memory of maximum...

Page 20: ...ation for the position of each module You may need to access the inside of the instrument to add or re place internal modules Use a flat screwdriver to unlock the upper clips marked with A Then unlock...

Page 21: ...Hz Criteria A 61000 4 11 0 1 cycle Criteria A 40 10 cycles Criteria A 70 25 cycles Criteria B 0 250 cycles Criteria B Barber del Vall s May 2014 Daniel Junc Quality Manager 1 25 Warranty 1 26 CE decla...

Page 22: ...tandalone for delayed installation as they do not require soldering or special configuration 2 Output and control modules 2 1 Module R1 2 2 Module AO Terminal A Common Terminal B NO Normally Open Term...

Page 23: ...module for K Series of panel meters ASCII protocol with Master Slave archi tecture Addressable with up to 31 modules Frames codified in rep resentable ASCII characters codes 32 to 255 directly visibl...

Page 24: ...patible with standard R1 modules The R2 R4 and R6 modules can be ordered pre installed into a K Series panel meter or standalone for delayed installation as they do not require soldering or special co...

Page 25: ...FEMA ELECTR NICA Series K K40 C1 25 T h i s p a g e b l a n k...

Page 26: ...nd remove the front filter Inter nal press buttons for configuration are accessible Optionally request the instrument preconfigured from factory Without front keypad Front IP65 protection with sealing...

Page 27: ...96x48mm instruments Front IP65 protector for M Se ries and K Series panel meters Benchtop housing for M Series and K Series panel meters Handle with three selectable positions Power connector with man...

Page 28: ...info fema es www fema es Panel meters Standard 96x48mm Panel meters Compact 72x36mm Panel meters Miniature 48x24mm Large format meters Signal converters Isolators Bar meters Low cost Customized instr...

Reviews: