FEMA ELECTRÓNICA . Series K . K40-C1
15
At the ‘
Password
’ (‘
PASS
’) menu select a 4 digit code to block access
to the ‘configuration menu’. Instrument configuration will not be ac-
cessible to non authorized personnel. To activate the ‘
Password
’ se-
lect ‘
on
’ and introduce the code.
The code will be requested when trying to access the ‘configuration
menu
’ (key ‘SQ’ (
<
)). The ‘
fast access
’ menu is not password pro-
tected.
The ‘
Version
’ (‘
VEr
’) menu informs of the current firmware version
installed in the module.
1.19.16 Menus ‘Overrange / underrange’
At the ‘
Brightness
’ (‘
LIGh
’) menu select the light intensity for the
front leds. With this function it is possible to adapt the instrument to
the environment light intensity.
1.19.18 Function ‘Password’
Menus ‘
OPt.1
’, ‘
OPt.2
’ and ‘
OPt.3
’ give access to the ‘configuration
menus
’ of the output and control modules installed at slots Opt.1,
Opt.2 and Opt.3.
See section
for a list of output and control modules available for
each slot. The ‘configuration menu’ of each module is described at
the User’s Manual of each module.
1.19.19 Factory reset
At the ‘
Factory reset
’ (‘
FAct
’) menu, select ‘
yes
’ to load the default
factory configuration for the instrument (see section 1.21).
1.19.20 Firmware version
1.19.21 Brightness
The ‘
Counter overrange
’ (‘
c.orG
’) and ‘
Counter underrange
’ (‘
c.urG
’)
parameters configure the behavior of the instrument when reading
is higher than ‘9999’ (overrange) or lower than ‘-1999’ (underrange).
Select ‘
FLSH
’ to enter reading into flash mode. Select ‘
to_0
’ to apply
a reset to ‘0’. Select ‘
to_P
’ to apply a reset to preset value.
1.19.22 Access to optional modules
1.19.17 Left zeros
The ‘
Left zeros
’ (‘
L.ZEr
’) parameter controls the left zeros on or off.
1.19 Configuration menu (cont.)
Counter
overrange
Flash
To zero
To preset
Counter
underrange
Flash
To zero
To preset
Left zeros
With left zeros
Without left zeros
Key LE
Front reset
Alarm unlock
No function
Option
1
Configuration menu for the module installed at Opt.1
Option
2
Configuration menu for the module installed at Opt.2
Option
3
Configuration menu for the module installed at Opt.3
Password
Version
Factory reset
Minimum
Brightness
Maximum
Standard
The ‘LE’ (
3
) key at the front of the instrument can be configured to
activate several functions. Only one function can be assigned to the
‘LE’ (
3
) key
• the ‘
No function
’ (‘
nonE
’)
value assigns no function.
• the ‘
Front reset
’ (‘
F.rSt
’) value asigns the reset funtion.
• the ‘
Alarm unlock
’ (‘
A.Lck
’)
value assigns the manual unlock of the
alarms function, for instruments with the ‘
Locked alarms
’ (‘
A.Lck
’)
function activated (see section 1.19.11)
1.19.15 Menu ‘Key LE’