7
TATE DIGITAL WALL MOUNTED MIXER INSTALLATION GUIDE
SCOPE OF APPLICATION
Under Basin (Recommended)
Wire and Data Cable
must be installed prior
to the wall lining.
It is recommended
that the Data Cable is
installed in conduit for
ease of maintenance.
Warning:
Please ensure that all electrical
installations are installed by a registered
electrician and complies with the Electrical
(Safety) Regulations of NZ.
Important:
The Digital Mixer must have an
access panel.
Hot in
Cold in
Spout Outlet
Cable length
10m max.
Digital Mixer
Control Unit
Power supply
must be within
1m from the
digital mixer
Control cable
Pipework in
Pipework out
Power supply
Important: The Digital Mixer must
be accessible and should not be
sealed in the wall
78mm
115mm
45mm
MEASUREMENTS