TST
Erweiterte Inbetriebnahme
WU
FEIG ELECTRONIC GmbH
Seite 11 von 18
WU_erweiterte_ Inbetriebnahme4_GB.doc
Table 1: Input profiles
Value
Function
Contact
type
End position
Hold-open
time
Clear
time
Direction
ON
Delay
OFF Delay
LCD-Text
Test
0000
Input
deactivated
0101
OPEN 1
Upper
With
With
Both
Without
Without
OPEN
No
0102
OPEN 1
N.O.
Intermediate stop
With
With
Both
Without
Without
OPEN
No
0103
OPEN airlock
N.O.
Intermediate stop
With
With
Both
Without
Without
OPEN
No
0104
OPEN 1
N.O.
Intermediate stop
With
With
from outside
Without
Without
OPEN
No
0105
OPEN 2
N.O.
Upper
With
With
Both
Without
Without
OPEN
No
0106
OPEN 2
N.O.
Upper
With
With
from inside
Without
Without
OPEN
No
0107
OPEN 4
N.O.
Upper
With
With
Both
Without
Without
OPEN
No
0108
OPEN 2
N.O.
Intermediate stop
With
With
Both
Without
Without
OPEN
No
0109
OPEN 3
N.O.
Intermediate stop
With
With
Both
Without
Without
OPEN
No
0110
OPEN 1
N.O.
Upper
With
With
from outside
Without
Without
OPEN
No
0111
OPEN 1
N.C.
Upper
With
Without
Both
Without
Without
OPEN
No
0112
OPEN 1
N.O.
Upper
Without
With
Both
Without
Without
OPEN
No
0114
OPEN airlock
N.O.
Intermediate stop
With
With
from inside
Without
Without
OPEN
No
0116
OPEN 1
N.O.
Upper
Without
With
from outside
Without
Without
OPEN
No
0117
OPEN 1
N.O.
Upper
Without
With
from inside
Without
Without
OPEN
No
0120
OPEN 2
N.O.
Upper
With
Without
from inside
Without
Without
OPEN
No
0121
OPEN 1
N.O.
Upper
With
Without
from outside
Without
Without
OPEN
No
0124
OPEN 2
N.O.
Intermediate stop
With
With
from inside
Without
Without
OPEN intern
No
0125
OPEN 2
N.O.
Upper
With
With
from inside
Without
Without
OPEN intern
No
0129
OPEN 2
N.O.
Intermediate stop
With
With
from outside
Without
Without
OPEN extern
No
0201
Pull switch
OPEN -> Endposition
-> CLOSE -> OPEN
N.O.
1. Intermediate
stop
2. Upper
With
With
Both
Without
Without
Pull switch
No
0202
Pull switch
OPEN -> Endposition
-> CLOSE -> OPEN
N.O.
1. Intermediate
stop
2. Upper
Without
With
Both
Without
Without
Pull switch
No
1
N.C. = normally closed, N.O. = normally open
2
OPEN 3 and OPEN 4 cannot be locked out.
3
N.C. = normally closed, N.O. = normally open