TST
Expanded Startup
WU
FEIG ELECTRONIC GmbH
Page 12 of 18
WU_erweiterte_ Inbetriebnahme4_GB.doc
Value
Function
Contact
type
End position
Hold-open
time
Clear
time
Direction
ON
Delay
OFF Delay
LCD-Text
Test
0203
Pull switch
OPEN -> Endposition
-> CLOSE -> OPEN
N.O.
1. Intermediate
stop
2. Upper
3. Pull straight up 2x
Without
With
Both
Without
Without
Pull switch
No
0204
Pull switch
OPEN -> Endposition
-> CLOSE -> OPEN
N.O.
Upper
Without
With
Both
Without
Without
Pull switch
No
0207
Pull switch
OPEN -> Endposition
-> CLOSE -> OPEN
N.O.
Intermediate stop
With
With
From inside
Without
Without
Pull Swit.int
No
0208
Pull switch
OPEN -> Endposition
-> CLOSE -> OPEN
N.O.
1. Intermediate
stop
2. Upper
With
With
From outside
Without
Without
Pull Swit.ext
No
0209
Pull switch
OPEN -> STOP ->
CLOSE -> STOP
N.O.
1. Intermediate
stop
2. Upper
Without
With
Both
Without
Without
Pull switch
No
0301
Permanent OPEN
N.O.
1. Intermediate
stop
2. Upper
Without
Without
Both
Without
Without
Perm. Open
No
0304
Permanent OPEN
N.O.
Upper
Without
Without
No
Without
Without
Perm. Open
No
0401
Stop
N.C.
-
-
-
-
Without
Without
Stop
No
0402
Stop
N.O.
-
-
-
-
Without
Without
Stop
No
0403
Stop, Reset possible
N.C.
-
-
-
-
Without
Without
Stop
No
0404
Stop. Reset possible
N.O.
-
-
-
-
Without
Without
Stop
No
0501
Photoeye
N.C.
as before
as before
With
Both
Without
Without
Photoeye
No
0502
Photoeye with
through-travel
sensing 1
N.C.
as before
as before
With
Both
Without
Without
Photo-eye
No
0504
Photoeye
N.C.
as before
Min. hold-
open time
With
Both
Without
Without
Photo-eye
No