OBID
i-scan
®
Application-Note
ID ISC.ANT800/600-DA
FEIG ELECTRONIC GmbH
Seite 23 von 26
N50101-0e-ID-B.doc
4.3. Testing the Performance
For this performance test we will be assuming the conditions described in the section
. The indicated ranges and read areas will change correspondingly when different labels are
used. For testing the ISO Inventory function has to be activated like in
For the different label orientations you have to use different test methods, which are described
below:
4.3.1. Testing parallel Label Orientation
Begin the test by checking the read range
outside
the gate (see Figure 10, position
d
), assuming
the configuration and local conditions permit. Assuming a parallel label orientation with respect to
the antenna facing out, a read range at the centre of the antenna should be 60-65 cm. This test
should be repeated for both antennas. The read range may vary here by a few centimeters (ap-
prox.
±
2.5 cm).
Now slowly move the label vertically and horizontal in the gate as shown in Figure 10. The label
should always be read.
Figure 10: Performance Test with parallel Label Orientation