4. Starting up and Testing the Gate
After installing and tuning the antennas you can check the correct functioning of the gate using the
Reader, the service software and a Smart Label. If an SWR meter was used when tuning the an-
tennas, remove it now.
4.1. Checking the Noise Level
Step
Procedure
Note
1
Fasten a label to one of the
antennas
Use adhesive tape for example to attach the label
2
Click on “Commands”
button
3
Multiplexer:
[0xDD] Channel Select
Cascade Level: 1
Output Channel Input 1: 1
Output Channel Input 2: 8
4
Send Command to Reader
5
Click on “Test and
Measurement” button
6
Select the „Noise Level“
function and start by
clicking on the „Start“
button.
7
Nominal noise level values:
Average:
400-750mV
Difference (Max-Min):