1.2. Required Components
The following are required to construct the gate:
-
Qty. 1 ID ISC.LR200-B
-
Qty. 1 ID ISC.ANT.MUX-A
-
Qty. 1 ID ISC.ANT.PS-B
-
Qty. 4/6 ID ISC.ANT800/600-DA
-
Qty. 2 ID ISC.ANT.CS
-
Qty. 1 ID ISC.ANT.SC
-
Qty. 3/5 EMC ring core
Supplier: Würth Elektronik GmbH & Co. KG, Best.-Nr. 742 701 4
-
Qty. 2 Koaxialcable 18cm with SMA-connectors
The cables on the ID ISC.ANT800/600-DA antennas are approx. 3.5 m long each. The connection
between the power splitter ID ISC.ANT.PS-B and reader ID ISC.LR200-B is made by the 2.9m
cable from the ID ISC.ANT.CS cable set. The power splitter ID ISC.ANT.PS-B and the multiplexer
ID ISC.ANT.MUX-A are connected by the 18 cm cables ID ISC.ANT.SC. This means the reader
needs to be installed near the antennas.
For greater distances between reader and antennas, the ID ISC.ANT.EC extension can be used to
increase the length of the antenna cable and/or the cable between reader and power splitter by
7.20m. This will however result in a slight reduction in performance.
For cable extension the following is required:
-
ID ISC.ANT.EC
For startup you will need the service software
ISOStart Version 6.06 or higher and
DATuningTool
on a PC running under Windows. The service software can be found on the
OBID
i-scan
®
CD
available from FEIG ELECTRONIC GmbH. Also recommended for checking purposes is an SWR
meter with SMA jacks. For more detailed information, see