4.2. Reading out a Serial Number
Step
Vorgang
Hinweis
1
Fasten a label to one of the
antennas
Use adhesive tape for example to attach the label
2
Click on “Commands”
button
3
Multiplexer:
[0xDD] Channel Select
Cascade Level: 1
Output Channel Input 1: 1
Output Channel Input 2: 8
4
Send Command to Reader
5
Click on “Test and
Measurement” button
6
Select „ISO Inventory“
function and start by
clicking on the „Start“
button.
The serial number and la-
bel type are displayed in
the window.
7
Test the performance
8
Repeat Step 2 to 7 for
Output Channel Input1: 2
Output Channel Input2: 7
9
For a Gate with 6 antennas repeat step 2 to 7 for
Output Channel Input1: 3
Output Channel Input2: 6