9. Do not damage the power cable.

 Never carry the compressor by its 

cable and never pull on it to disconnect it from the power socket. Keep 

the cable away from sources of heat, greasy areas, and sharp objects. 

10.  Never  overestimate  your  strength

.  Always  keep  a  firm  position 

and maintain your balance. 

11.  Always  care  for  your  compressor  carefully.

  Keep  your 

compressor  clean  for  better  performance  and  more  safety.  Follow  the 

instructions  for  maintenance.  Check  the  power  cable  regularly  and,  in 

the event of a defect, have it replaced by a qualified service technician. 

Check the extensions regularly and replace them if they are damaged. 

Keep the handles dry, clean and free of grease or oil. 

12.  Unplug  the  tools.

  In  case  of  non-use  or  maintenance  of  your 

compressor. 

13. Remove the tools on your compressor.

 Make a habit of checking 

that the adjustment tensioners are removed before activating the tool. 

14.  Avoid  untimely  start-ups.

  Make  sure  the  switch  is  in  the  OFF 

position before plugging it into the mains. 

15.  Use  only  extension  cords  for  outdoor  use.

  Only  use  extension 

cords designed for this purpose. 

16. Always be on your guard.

 Watch your work. Use common sense. 

Do not use the compressor if you are tired. 

17. Check for faulty or damaged parts of your compressor.

 Before 

using your compressor again, we strongly recommend that you carefully 

check  the  protective  accessories  and  other  parts  to  see  if  the unit  will 

work properly. Check that the moving parts are properly secured, that no 

parts are broken, that the unit is properly assembled and that no other 

factor could affect its operation. Unless otherwise stated in the operating 

instructions,  any  damaged  protective  gear  or  damaged  parts  must  be 

repaired  by  a  qualified  and  approved  company.  Never  use  the 

compressor if the switch does not activate or deactivate the tool. 

18. Use original or equivalent replacement parts recommended by 

the manufacturer or dealer.

 The use of accessories other than those 

mentioned  in  the  user  manual  may  cause  damage  and  constitute  a 

source of injury. 

19.  Always  have  the  compressor  serviced  by  an  authorized 

professional  service  center.

  This  compressor  complies  with  safety 

standards.  Repairs  can  only  be  carried  out  by  qualified  service,  with 

original spare parts. If this condition is not met, the user could be faced 

with considerable danger. 

Summary of Contents for FC200L

Page 1: ...ORIGINAL INSTRUCTIONS COMPRESSOR INSTRUCTION MANUAL FC200L Feider ZI 32 RUE ARISTIDE BERGES 31270 CUGNAUX FRANCE Read instructions before use Keep for future reference ...

Page 2: ...o handle highly reliable and quiet it is suitable for many applications in the mechanic and chemical industries for spraying and decorating for automatic control systems as well as in any other area requiring compressed air II DESCRIPTION 1 Wheel 2 Transport handle 3 Air tank 4 Fan and fan cover 5 Compressor 6 Transport handle 7 Pressure gauge 8 Exit valve ...

Page 3: ...ntermediate temperature 170 200 discharge temperature 10 40 Pressures 0 Bar Intermediate pressure and discharge 0 8Bar Pressure and limiting temperatures of the lubrication system 8Bar 200 Note Noise emission was measured according to the expected conditions by the standards EN1012 and EN ISO 2158 IV Delivery checking After unpacking the machine check the contents of the carton for the possible pr...

Page 4: ...ructions given in the manual will help you to use the device more efficiently and to reduce the risks Do not use the portable compressor with the door or fence open Read instruction manual Wear hearing protection Do not open the valve before connecting the air hose The device can turn on automatically without warning Risk of high temperature Risk of electric shock ...

Page 5: ...here is a risk of fire or explosion 3 Protection against electric shock Avoid getting your body in contact with grounded surfaces such as pipes radiators cooking modules refrigerators 4 Keep children away from the work area Never let people touch the compressor the power cable or the extension cord 5 Store the compressor properly If you do not use the compressor keep it in a dry place out of the r...

Page 6: ...nsion cords designed for this purpose 16 Always be on your guard Watch your work Use common sense Do not use the compressor if you are tired 17 Check for faulty or damaged parts of your compressor Before using your compressor again we strongly recommend that you carefully check the protective accessories and other parts to see if the unit will work properly Check that the moving parts are properly...

Page 7: ...formed gases that can move in the breathing air must be kept at acceptable levels C Specific safety instructions 1 Before turning the machine mount the air filter vacuum breaker wheels and pads Fig 2 Fig 2 2 Never unscrew the connecting pieces when the tank is pressurized 3 Never disassemble an electrical component before unplugging the unit 4 Never adjust the safety valve without reason 5 Never u...

Page 8: ... off immediately 19 If the motor gets stuck due to excessively high temperature stop and then disconnect the machine and find the cause 20 If at a pressure greater than 8 bar the machine does not stop automatically immediately switch off the machine by hand and find the cause 21 If a strange noise has occurred turn off the machine immediately and look for the cause 22 If the oil level in the compr...

Page 9: ...is an overload protector on the compressor 12A If the current exceeds 12A the overload protector will start and stop the compressor automatically After 2 3 minutes press the overload protector button to restart the compressor The ambient temperature for the air compressor is 5 40 degrees Use the air compressor oil according to the ambient temperature for the air compressor 5 40 degrees The user mu...

Page 10: ...nly 1 The place of use of the compressor must be clean dry and ventilated 2 Conditions of use Use the compressor only at a temperature between 0 and 35 C 3 Be sure to use a voltage 5 of the recommended voltage 4 Maintain the oil level at the red circle filler cap 5 Use SAE30 or L DAB100 compressor oil above 10 C and SAE10 or L DAB68 below 10 C 6 Open the outlet valve set the pressure switch to ON ...

Page 11: ...l valve and turn it clockwise or counterclockwise to increase or decrease the pressure Fig 4 3 To stop the compressor simply turn the pressure switch knob OFF Fig 4 VIII Maintenance TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Turn the Power Switch OFF and unplug the compressor from its electrical outlet before performing any inspection maintenance or cleaning procedures TO PREVENT SERIOUS ...

Page 12: ...Check for air leaks to check for air leaks apply soapy water to joints while the Air Compressor is pressurized Look for air bubbles Wipe off any oil or dirt from the compressor To clean the compressor surface wipe with a damp cloth using a mild detergent or mild solvent Draining Moisture from the Tank It must be used daily to release all trapped air and moisture from the Tank This will eliminate c...

Page 13: ...n or wait for an automatic restart 4 Repair or replace 5 Check and repair 6 Check and repair Low pressure 1 Air leak in the safety valve 2 Air filter more or less clogged 3 Defectiveness in other valves 1 Check repair change if necessary 2 Clean change if necessary 3 Check change if necessary Clamping the main compresso r 1 Moving parts overheated due to lack of oil 2 Moving parts are damaged or b...

Page 14: ...12 XI Nomenclature ...

Page 15: ...e Machine 2006 42 EC Directive EMC 2014 30 EU Directive RoHS 2011 65 EU Directive NOISE 2000 14 EC Annex VI 2005 88 EC Also in conformity with the following standards EN 1012 1 2010 EN 61000 6 1 2007 EN 61000 6 3 2007 A1 2011 EN 62321 2009 Sound power level 95 2dB A K 1 96dB A Guarantee sound power level 97dB A Responsible of technical file M Olivier Patriarca Cugnaux 25 10 2018 Philippe MARIE PDG...

Page 16: ...European Directive 2012 19 EU on waste electrical and electronic equipment and its implementation into national law electrical products used must be collected separately and disposed of at collection points provided for this purpose Talk with your local authorities or dealer for advice on recycling ...