III. 

  Technical specifications 

Alimentation   

220-230V AC / 50Hz 

Power 

2200W 

Type of motor 

2 poles 

Max rotational speed 

950/min

 

Max discharge pressure 

0.8 mPa / 8 bars 

Air flow 

290 L/MIN 
 

Outlet diameter 

1/4” 

Volume of air tank 

200L 

Weight 

94 kg 
28kg 
30kg 
38kg 

Class 

Degree of protection   

IP20 

Sound power level 

95.2dB(A)

K=1,96dB(A) 

Sound pressure level 

75,2dB(A)

  K=1,96dB(A) 

Guarantee sound power level 

97dB(A) 

 

Inlet  temperature:  10 

  -40 

,  intermediate  temperature:  170-200 

discharge temperature: 10 

 -40 

   Pressures: 0 Bar 

Intermediate pressure and discharge: 0 ~ 8Bar. 

   Pressure and limiting temperatures of the lubrication system: 8Bar, 200 

 

  

Note: Noise emission was measured according to the expected conditions 
by the standards EN1012 and EN ISO 2158. 
 

IV. 

Delivery checking   

After unpacking the machine, check the contents of the carton for the 
possible  presence  of  damage  due  to  transport.  Notify  the  dealer, 
carrier and / or manufacturer immediately in the event of a claim. Be 
aware that subsequent claims are no longer accepted.

   

 

 

N° 

Designation 

Quantity   

Air compressor 

Air filter 

Summary of Contents for FC200L

Page 1: ...ORIGINAL INSTRUCTIONS COMPRESSOR INSTRUCTION MANUAL FC200L Feider ZI 32 RUE ARISTIDE BERGES 31270 CUGNAUX FRANCE Read instructions before use Keep for future reference ...

Page 2: ...o handle highly reliable and quiet it is suitable for many applications in the mechanic and chemical industries for spraying and decorating for automatic control systems as well as in any other area requiring compressed air II DESCRIPTION 1 Wheel 2 Transport handle 3 Air tank 4 Fan and fan cover 5 Compressor 6 Transport handle 7 Pressure gauge 8 Exit valve ...

Page 3: ...ntermediate temperature 170 200 discharge temperature 10 40 Pressures 0 Bar Intermediate pressure and discharge 0 8Bar Pressure and limiting temperatures of the lubrication system 8Bar 200 Note Noise emission was measured according to the expected conditions by the standards EN1012 and EN ISO 2158 IV Delivery checking After unpacking the machine check the contents of the carton for the possible pr...

Page 4: ...ructions given in the manual will help you to use the device more efficiently and to reduce the risks Do not use the portable compressor with the door or fence open Read instruction manual Wear hearing protection Do not open the valve before connecting the air hose The device can turn on automatically without warning Risk of high temperature Risk of electric shock ...

Page 5: ...here is a risk of fire or explosion 3 Protection against electric shock Avoid getting your body in contact with grounded surfaces such as pipes radiators cooking modules refrigerators 4 Keep children away from the work area Never let people touch the compressor the power cable or the extension cord 5 Store the compressor properly If you do not use the compressor keep it in a dry place out of the r...

Page 6: ...nsion cords designed for this purpose 16 Always be on your guard Watch your work Use common sense Do not use the compressor if you are tired 17 Check for faulty or damaged parts of your compressor Before using your compressor again we strongly recommend that you carefully check the protective accessories and other parts to see if the unit will work properly Check that the moving parts are properly...

Page 7: ...formed gases that can move in the breathing air must be kept at acceptable levels C Specific safety instructions 1 Before turning the machine mount the air filter vacuum breaker wheels and pads Fig 2 Fig 2 2 Never unscrew the connecting pieces when the tank is pressurized 3 Never disassemble an electrical component before unplugging the unit 4 Never adjust the safety valve without reason 5 Never u...

Page 8: ... off immediately 19 If the motor gets stuck due to excessively high temperature stop and then disconnect the machine and find the cause 20 If at a pressure greater than 8 bar the machine does not stop automatically immediately switch off the machine by hand and find the cause 21 If a strange noise has occurred turn off the machine immediately and look for the cause 22 If the oil level in the compr...

Page 9: ...is an overload protector on the compressor 12A If the current exceeds 12A the overload protector will start and stop the compressor automatically After 2 3 minutes press the overload protector button to restart the compressor The ambient temperature for the air compressor is 5 40 degrees Use the air compressor oil according to the ambient temperature for the air compressor 5 40 degrees The user mu...

Page 10: ...nly 1 The place of use of the compressor must be clean dry and ventilated 2 Conditions of use Use the compressor only at a temperature between 0 and 35 C 3 Be sure to use a voltage 5 of the recommended voltage 4 Maintain the oil level at the red circle filler cap 5 Use SAE30 or L DAB100 compressor oil above 10 C and SAE10 or L DAB68 below 10 C 6 Open the outlet valve set the pressure switch to ON ...

Page 11: ...l valve and turn it clockwise or counterclockwise to increase or decrease the pressure Fig 4 3 To stop the compressor simply turn the pressure switch knob OFF Fig 4 VIII Maintenance TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Turn the Power Switch OFF and unplug the compressor from its electrical outlet before performing any inspection maintenance or cleaning procedures TO PREVENT SERIOUS ...

Page 12: ...Check for air leaks to check for air leaks apply soapy water to joints while the Air Compressor is pressurized Look for air bubbles Wipe off any oil or dirt from the compressor To clean the compressor surface wipe with a damp cloth using a mild detergent or mild solvent Draining Moisture from the Tank It must be used daily to release all trapped air and moisture from the Tank This will eliminate c...

Page 13: ...n or wait for an automatic restart 4 Repair or replace 5 Check and repair 6 Check and repair Low pressure 1 Air leak in the safety valve 2 Air filter more or less clogged 3 Defectiveness in other valves 1 Check repair change if necessary 2 Clean change if necessary 3 Check change if necessary Clamping the main compresso r 1 Moving parts overheated due to lack of oil 2 Moving parts are damaged or b...

Page 14: ...12 XI Nomenclature ...

Page 15: ...e Machine 2006 42 EC Directive EMC 2014 30 EU Directive RoHS 2011 65 EU Directive NOISE 2000 14 EC Annex VI 2005 88 EC Also in conformity with the following standards EN 1012 1 2010 EN 61000 6 1 2007 EN 61000 6 3 2007 A1 2011 EN 62321 2009 Sound power level 95 2dB A K 1 96dB A Guarantee sound power level 97dB A Responsible of technical file M Olivier Patriarca Cugnaux 25 10 2018 Philippe MARIE PDG...

Page 16: ...European Directive 2012 19 EU on waste electrical and electronic equipment and its implementation into national law electrical products used must be collected separately and disposed of at collection points provided for this purpose Talk with your local authorities or dealer for advice on recycling ...