R E A D M E F I R S T !

IMPORTANT NOTE:

As you follow these

instructions, you will notice warning and caution
symbols. This blocked information is important
for the safe and efficient installation and opera-
tion of this generator. These are types of poten-
tial hazards that may occur during this installa-
tion and operation:

states a hazard may cause seri-

ous injury or death if precautions are not fol-
lowed.

signals a situation where minor

injury or product damage may occur if you do
not follow instructions.

is used to address practices not

related to physical injury.

IMPORTANT NOTE:

This highlights infor-

mation that is especially relevant to a problem-
free installation.

All information in these instructions is based on
the latest product information available at the
time of publication. Sussman-Automatic
Corporation reserves the right to make changes
at any time without notice. More current instruc-
tions may be available at www.mrsteam.com.

When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:

IMPORTANT SAFETY INSTRUCTIONS

1.

READ AND FOLLOW ALL INSTRUCTIONS

2.

Do not permit children under the age of 16

to use this steambath.

3.

To reduce the risk of injury:

A. The wet surfaces of steam enclosures may be slippery. Use care when

entering or leaving.

B. The steam head is hot. Do not touch the steam head and avoid the

steam near the steam head.

C. Prolonged use of the steam system can raise excessively the internal

human body temperature and impair the body’s ability to regulate its
internal temperature (hyperthermia). Limit your use of steam to 10-15
minutes until you are certain of your body’s reaction.

D. Excessive temperatures have a high potential for causing fetal damage

during the early months of pregnancy. Pregnancy or possibly pregnant
women should consult a physician regarding correct exposure.

E. Obese persons and persons with a history of heart disease, low or high

blood pressure, circulatory system problems, or diabetes should consult
a physician before using a steambath.

F. Persons using medication should consult a physician before using a

steambath since some medication may induce drowsiness while other
medications may affect heart rate, blood pressure and circulation.

A warning placard has been provided in the Information
envelope. This placard is an essential part of providing
a safe environment for steam room users. This placard
must be mounted to the wall of the shower or steam
enclosure, at a point visible to all users. Failure to
mount this placard may result in serious injury or death.

SAVE THESE INSTRUCTIONS

1

mr

.

steam

®

C L U B T H E R A P Y

Installation, Operating & Maintenance Manual

_________________________________________________________________________________________

STEAM ROOM BENEFITS

Steam bathing is a communal activity. Enjoy steam together with friends. Relax, knowing
that steam may be a natural detox. Here are some possible benefits of steam bathing:

- Cleanses, nourishes, and hydrates skin

- Boosts metabolism

- Provides relief for respiratory ailments such as colds, flu, allergies, and asthma

- Reduces stress and promotes restful sleep

Follow your steambath with a refreshing shower.

If you would like your own personal steam bath at home contact us at mrsteam.com

REDUCE THE RISK OF OVERHEATING AND SCALDING

1. Exit immediately if uncomfortable, dizzy or sleepy. Staying too long in a

heated area is capable of causing overheating.

2. Children under the age of 16 should not use the steam bath.
3. Check with a doctor before use if pregnant, diabetic, in poor health or

under medical care.

4. Breathing heated air in conjunction with consumption of alcohol, drugs or

medication is capable of causing unconsciousness.

5. Do not contact steam head or steam at the steam head.

REDUCE THE RISK OF SLIPPING AND FALL INJURY

Use care when entering or exiting the steam room, floor may be slippery.

Note:

For additional safety considerations see owner's manual.

MrSteam 43-20 34th Street, Long island City NY 11101 1-800-76-STEAM www.mrsteam.com

HYPERTHERMIA

occurs when the internal temperature

of the body reaches a level several degrees above the
normal body temperature of 98.6° F. The symptoms of
hyperthermia include an increase in the internal tem-
perature of the body, dizziness, lethargy, drowsiness,
and fainting. The effects of hyperthermia include:
a) Failure to perceive heat;
b) Failure to recognize the need to exit the steambath;
c) Unawareness of impending risk;
d) Fetal damage in pregnant women;
e) Physical inability to exit the steambath

and

f) Unconsciousness.

The use of alcohol, drugs, or medica-

tion can greatly increase the risk of hyperthermia.

not actual size

Summary of Contents for mr. steam Club Therapy CT6E

Page 1: ...mr steam Feel Good Inc Club Therapy Steambath Generator Systems Installation Operation Maintenance Manual Models CT6E CT9E CT12E CT15E Installation Operation Maintenance Manual...

Page 2: ...ical Specifications Field Power Wiring 9 Wiring Diagrams 10 Initial Start Up Checkout Maintenance Generator Operations and Troubleshooting 11 System Status Codes Liquid Level Control Board 12 AutoFlus...

Page 3: ...blood pressure and circulation A warning placard has been provided in the Information envelope This placard is an essential part of providing a safe environment for steam room users This placard must...

Page 4: ...to be installed inside the steam room when the control is mounted outside the steam room Steam Generators Specification Chart Amps for Total Adj Wire Water Usage Shipping Model No KW 240v 1PH Room Vo...

Page 5: ...r shipment by MrSteam the following must be reviewed for proper safe and enjoyable steam bathing 1 Verify that the model and accessories specifications are cor rect for the incoming line voltage 2 Ins...

Page 6: ...rovide supports under steam generator when wall mounting Keyhole slots are provided for wall mounting Insure the steam generator is properly secured and level when mounting with keyhole slots 6 Instal...

Page 7: ...formation Remote Sensor see page 16 CT SteamStop Control See page 17 for installation information iTempo Plus or iSteam Control See page 16 Field installed water supply line IMPORTANT Locate the remot...

Page 8: ...on Manual for installation information before the steam piping is installed at www mrsteam com technical downloads Steam Piping 1 2 NPT 1 Do not install any valve in steam piping Flow of steam must be...

Page 9: ...is finished STEP 4 After the wall has been finished mark on the nipple where the surface of the wall is Remove the nipple and measure the por tion that was in the wall the end to your mark Subtract 1...

Page 10: ...inches MM Water Inlet Steam Outlet Safety Valve AutoFlush Manual Drain Valve Generator Dimensions IMPORTANT NOTES Provide a minimum of 12 inches at both ends and top of the steam generator or as requi...

Page 11: ..._ 208 1 29 8 8 CT6E 150 6 0 3 17 10 10 240 1 25 8 8 3 14 12 12 ___________________________________________________________________________ 208 1 44 8 6 CT9E 360 9 0 3 25 8 8 240 1 38 8 8 3 22 10 10 __...

Page 12: ...T GRAY WHT BLUE RED WHT RED Remove Jumper when CU HTC is installed CONTROL BOARD CONTACTOR Heating Element To Probe AutoFlush CT SteamStop iTempo Plus or iSteam Control TRANSFORMER POWER INPUT L1 L2 F...

Page 13: ...from enclosure area turn shower on before opening door 4 If unit does not start and control does not turn ON control display does not light up then turn breaker off for 20 seconds and try again 5 Ref...

Page 14: ...rol Board EXPLANATION OF LED INDICATORS _____________________________________________________________________________________________________________________________________________ GREEN LED is ON wh...

Page 15: ...Open Drain Valve handle must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown Do not drain into a steam enclosure or any location where ac...

Page 16: ...oses not related to component identification Replacement Parts List ____________________________________________________________ Part No Description Product ___________________________________________...

Page 17: ...r or other purposes not related to component identification 15 Transformer Drain Line Liquid Level Control Board Fuses Water Inlet Water Feed Solenoid Safety Valve AutoFlush Valve Stainless Steel Tank...

Page 18: ...le length is 30 feet Insure that the control and or steam generator are located according ly An optional 60 foot cable is available PN 103990 60 for iTempo and PN 104117 60 for iSteam Contact a MrStea...

Page 19: ...sket The connector is keyed and will only connect in one orientation with the tab facing up LED indicator will light up when the generator is ON Using the CT SteamStop Control The CT SteamStop control...

Page 20: ...meWizard iButler iGenie iSizing iSteam iTempo iTempo Plus Making Wellness a Way of Life Music Therapy Spa Package Steam Genie Steam on Demand Steam Home SmartSizing SteamStart SteamStop SteamTherapy S...