background image

Do not route iSteam, iTempo/Plus, iTempo,

HomeWizard or iGenie control wiring inside conduit
together with power lines or close to hot water or steam
piping. Doing so may result in an inoperative or hazardous
installation.

Do Not alter or modify any MrSteam prod-

uct. Doing so may result in an inoperable or hazardous
installation and will void the warranty

IMPORTANT NOTES:

1. Turn power to the steam generator OFF before con-

necting the control to the generator. Failure to turn the
power off will result in an inoperable control.

2. Do not operate iSteam, iTempo/Plus, iTempo,

HomeWizard or iGenie controls with other than a
MrSteam iSteam or iTempo compatible steam genera-
tor. MrSteam steam generators with serial numbers
lower than 900000, or any other brand of steam gener-
ator are not to be operated with iTempo controls.
Doing so may result in an inoperative or hazardous
installation. If iSteam is used with a generator having
serial number less than 1174000, contact MrSteam
technical support for an upgraded PC board.

3. This document contains important safety, operation and

maintenance information. Leave this document with
management. Do not discard this document.

4. Discontinue use of the steam generator or control if the

steam generator is damaged or otherwise not function-
ing properly. Operating a damaged steam generator
may result in an inoperative or hazardous installation

16

mr

.

steam

®

C L U B T H E R A P Y

Controls

_________________________________________________________________________________________

Control Rough In

Refer to Installation Instructions for the specific control

IMPORTANT NOTE:

The control cables should be run in dedicated 1" conduit to facilitate installation and service.

1. Determine the desired installation location of the

control. The iSteam

®

, iTempo

and iTempo/Plus

controls are designed to be installed inside or out-
side the steam room as a matter of personal prefer-
ence. If the control is installed inside the steam
room the control must be located:

2. 4 -5 feet above the floor near the bather seating area
3. The control features an integral temperature sensor.

Locate the control in a location representative of the
desired steambathing temperatures.
Do not locate the control above or near the steam
head or direct steam emissions.

4. on a vertical wall

The control cable length is 30 feet. Insure that the
control and/or steam generator are located according-

ly. An optional 60 foot cable is available, PN 103990-60 for
iTempo and PN 104117-60 for iSteam. Contact a MrSteam
technical service representative if a 60 foot cable is required.

IMPORTANT NOTE:

If the control is installed outside the

steamroom a Remote Temperature Probe Part Number MSTS
must be installed inside the steam room, depending on the
control. Insure MrSteam steam generator is iSteam or iTempo
compatible and has a serial number 900000 or higher. If
iSteam is used with a generator having serial number less than
1174000, contact MrSteam technical support for an upgraded
PC board.

See instructions for the MSTS Temperature Probe (located in
the Control Installation Manual related to your specific control
package) before rough-in or installation of control.

Before Installing

Turn power to the steam generator OFF before connecting the
control to the generator. Failure to turn the power off will result in
an inoperable control.

To avoid unintentional steambath operation,

do not locate the control where other controls, accessories,
shower heads, valves, body sprays or similar within the show-
er could cause confusion or interfere with the MrSteam con-
trol’s intended use and function.

Do not use any iSteam

®

, iTempo/Plus

,

iTempo

, HomeWizard

or iGenie

®

controls without reading

and understanding its own manual and the MrSteam steam
generator Installation and Operation Manual. Failure to read
and understand these instructions may result in an inopera-
tive or hazardous installation.

The warning placard located in the documenta-

tion envelope must be read and permanently affixed in a con-
spicuous location near the steam room. Failure to read and affix
this warning placard in a conspicuous location may result in seri-
ous injury or death.

Install the iSteam, iTempo or iTempo/Plus controls according
to installation instructions. Failure to install according to
instructions will result in an inoperative control or hazardous
overheating or inadequate heating of the steam room.
If an iSteam, iTempo or iTempo/Plus control is installed out-
side the steam room a Remote Temperature Probe (PN
MSTS) must be installed inside the steam room per installa-
tion instructions supplied with the Remote Temperature
Probe. Failure to install according to instructions will result in
an inoperative control and overheating of the steam room.

Control Installation

Refer to Control Manual for specific installation requirements

Summary of Contents for mr. steam Club Therapy CT6E

Page 1: ...mr steam Feel Good Inc Club Therapy Steambath Generator Systems Installation Operation Maintenance Manual Models CT6E CT9E CT12E CT15E Installation Operation Maintenance Manual...

Page 2: ...ical Specifications Field Power Wiring 9 Wiring Diagrams 10 Initial Start Up Checkout Maintenance Generator Operations and Troubleshooting 11 System Status Codes Liquid Level Control Board 12 AutoFlus...

Page 3: ...blood pressure and circulation A warning placard has been provided in the Information envelope This placard is an essential part of providing a safe environment for steam room users This placard must...

Page 4: ...to be installed inside the steam room when the control is mounted outside the steam room Steam Generators Specification Chart Amps for Total Adj Wire Water Usage Shipping Model No KW 240v 1PH Room Vo...

Page 5: ...r shipment by MrSteam the following must be reviewed for proper safe and enjoyable steam bathing 1 Verify that the model and accessories specifications are cor rect for the incoming line voltage 2 Ins...

Page 6: ...rovide supports under steam generator when wall mounting Keyhole slots are provided for wall mounting Insure the steam generator is properly secured and level when mounting with keyhole slots 6 Instal...

Page 7: ...formation Remote Sensor see page 16 CT SteamStop Control See page 17 for installation information iTempo Plus or iSteam Control See page 16 Field installed water supply line IMPORTANT Locate the remot...

Page 8: ...on Manual for installation information before the steam piping is installed at www mrsteam com technical downloads Steam Piping 1 2 NPT 1 Do not install any valve in steam piping Flow of steam must be...

Page 9: ...is finished STEP 4 After the wall has been finished mark on the nipple where the surface of the wall is Remove the nipple and measure the por tion that was in the wall the end to your mark Subtract 1...

Page 10: ...inches MM Water Inlet Steam Outlet Safety Valve AutoFlush Manual Drain Valve Generator Dimensions IMPORTANT NOTES Provide a minimum of 12 inches at both ends and top of the steam generator or as requi...

Page 11: ..._ 208 1 29 8 8 CT6E 150 6 0 3 17 10 10 240 1 25 8 8 3 14 12 12 ___________________________________________________________________________ 208 1 44 8 6 CT9E 360 9 0 3 25 8 8 240 1 38 8 8 3 22 10 10 __...

Page 12: ...T GRAY WHT BLUE RED WHT RED Remove Jumper when CU HTC is installed CONTROL BOARD CONTACTOR Heating Element To Probe AutoFlush CT SteamStop iTempo Plus or iSteam Control TRANSFORMER POWER INPUT L1 L2 F...

Page 13: ...from enclosure area turn shower on before opening door 4 If unit does not start and control does not turn ON control display does not light up then turn breaker off for 20 seconds and try again 5 Ref...

Page 14: ...rol Board EXPLANATION OF LED INDICATORS _____________________________________________________________________________________________________________________________________________ GREEN LED is ON wh...

Page 15: ...Open Drain Valve handle must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown Do not drain into a steam enclosure or any location where ac...

Page 16: ...oses not related to component identification Replacement Parts List ____________________________________________________________ Part No Description Product ___________________________________________...

Page 17: ...r or other purposes not related to component identification 15 Transformer Drain Line Liquid Level Control Board Fuses Water Inlet Water Feed Solenoid Safety Valve AutoFlush Valve Stainless Steel Tank...

Page 18: ...le length is 30 feet Insure that the control and or steam generator are located according ly An optional 60 foot cable is available PN 103990 60 for iTempo and PN 104117 60 for iSteam Contact a MrStea...

Page 19: ...sket The connector is keyed and will only connect in one orientation with the tab facing up LED indicator will light up when the generator is ON Using the CT SteamStop Control The CT SteamStop control...

Page 20: ...meWizard iButler iGenie iSizing iSteam iTempo iTempo Plus Making Wellness a Way of Life Music Therapy Spa Package Steam Genie Steam on Demand Steam Home SmartSizing SteamStart SteamStop SteamTherapy S...

Reviews: