Installation, Operating & Maintenance Manual

_________________________________________________________________________________________

12

Force On

Test Button

Yellow

(Water Level)

Green

(Power)

Red

(Heater)

System Status Codes

The iTempo/Plus control may display a status code if the steam generator is not functioning properly.

Code

Code Meaning

Probable Cause

Suggested Remedy

H20

Water level is not

Water Supply is off

Turn on Water Supply

satisfied within 5 min.

Defective water feed solenoid

Check/replace water solenoid valve

Water feed probe not functioning

Check/clean probe.
Check probe wiring.

Drain Valve Open

Check/Close drain valve

AutoFlush not functioning

Check/Replace AutoFlush

Prr1

Temperature Probe Error

Control/Remote sensor cable cut

Replace Control Cable/Sensor

or Prr2

Internal problem with control/Remote Sensor Replace ControlSensor

Err1

Incorrect Field Supply Voltage Incorrect voltage supplied

Supply steam generator with the correct

(green light on liquid level

to Generator

voltage noted on the data plate label.

control board will be off)

Err2

Button on control is pressed

Control cover misalignment

Remove and reinstall control cover

for more than 5 minutes

Debris behind control cover

Remove control cover and clean cover,
control and keypad with a damp cloth

Err7

Liquid Level Control Board

Memory error in LLCB

Press ON/OFF to clear.

malfunction

Replace control if code remains.

Liquid Level Control Board -

EXPLANATION OF LED INDICATORS

_____________________________________________________________________________________________________________________________________________

GREEN

LED is ON when there is 208/240 Volt incoming power connected,
24 Volt transformer secondary output and on-board 5 Volt DC control power are present.

_____________________________________________________________________________________________________________________________________________

YELLOW

Water level indicator–LED is OFF when no water is detected (for more that 5 seconds). ON when
water level is satisfactory. For units with AutoFlush, if more than five hours have elapsed since
last usage and this LED is ON it is indicative of an AutoFlush or water level probe circuit malfunction.

_____________________________________________________________________________________________________________________________________________

RED

Contactor relay indicator–LED is ON when relay is closed and sending 24 Volts to the
contactor coil. (This LED comes ON if the generator is ON.)

_____________________________________________________________________________________________________________________________________________

FORCE ON

This button is for trouble shooting only and will operate if a control is connected or not.

TEST BUTTON Pressing the button again will shut the generator OFF.

The test button will only allow the generator to operate for 10 minutes.

_____________________________________________________________________________________________________________________________________________

Liquid Level Control Board

PN 104288

(shown without wiring)

Summary of Contents for mr. steam Club Therapy CT6E

Page 1: ...mr steam Feel Good Inc Club Therapy Steambath Generator Systems Installation Operation Maintenance Manual Models CT6E CT9E CT12E CT15E Installation Operation Maintenance Manual...

Page 2: ...ical Specifications Field Power Wiring 9 Wiring Diagrams 10 Initial Start Up Checkout Maintenance Generator Operations and Troubleshooting 11 System Status Codes Liquid Level Control Board 12 AutoFlus...

Page 3: ...blood pressure and circulation A warning placard has been provided in the Information envelope This placard is an essential part of providing a safe environment for steam room users This placard must...

Page 4: ...to be installed inside the steam room when the control is mounted outside the steam room Steam Generators Specification Chart Amps for Total Adj Wire Water Usage Shipping Model No KW 240v 1PH Room Vo...

Page 5: ...r shipment by MrSteam the following must be reviewed for proper safe and enjoyable steam bathing 1 Verify that the model and accessories specifications are cor rect for the incoming line voltage 2 Ins...

Page 6: ...rovide supports under steam generator when wall mounting Keyhole slots are provided for wall mounting Insure the steam generator is properly secured and level when mounting with keyhole slots 6 Instal...

Page 7: ...formation Remote Sensor see page 16 CT SteamStop Control See page 17 for installation information iTempo Plus or iSteam Control See page 16 Field installed water supply line IMPORTANT Locate the remot...

Page 8: ...on Manual for installation information before the steam piping is installed at www mrsteam com technical downloads Steam Piping 1 2 NPT 1 Do not install any valve in steam piping Flow of steam must be...

Page 9: ...is finished STEP 4 After the wall has been finished mark on the nipple where the surface of the wall is Remove the nipple and measure the por tion that was in the wall the end to your mark Subtract 1...

Page 10: ...inches MM Water Inlet Steam Outlet Safety Valve AutoFlush Manual Drain Valve Generator Dimensions IMPORTANT NOTES Provide a minimum of 12 inches at both ends and top of the steam generator or as requi...

Page 11: ..._ 208 1 29 8 8 CT6E 150 6 0 3 17 10 10 240 1 25 8 8 3 14 12 12 ___________________________________________________________________________ 208 1 44 8 6 CT9E 360 9 0 3 25 8 8 240 1 38 8 8 3 22 10 10 __...

Page 12: ...T GRAY WHT BLUE RED WHT RED Remove Jumper when CU HTC is installed CONTROL BOARD CONTACTOR Heating Element To Probe AutoFlush CT SteamStop iTempo Plus or iSteam Control TRANSFORMER POWER INPUT L1 L2 F...

Page 13: ...from enclosure area turn shower on before opening door 4 If unit does not start and control does not turn ON control display does not light up then turn breaker off for 20 seconds and try again 5 Ref...

Page 14: ...rol Board EXPLANATION OF LED INDICATORS _____________________________________________________________________________________________________________________________________________ GREEN LED is ON wh...

Page 15: ...Open Drain Valve handle must be aligned with brass nipple 4 Connect the AutoFlush System cord connector to the three pin connector as shown Do not drain into a steam enclosure or any location where ac...

Page 16: ...oses not related to component identification Replacement Parts List ____________________________________________________________ Part No Description Product ___________________________________________...

Page 17: ...r or other purposes not related to component identification 15 Transformer Drain Line Liquid Level Control Board Fuses Water Inlet Water Feed Solenoid Safety Valve AutoFlush Valve Stainless Steel Tank...

Page 18: ...le length is 30 feet Insure that the control and or steam generator are located according ly An optional 60 foot cable is available PN 103990 60 for iTempo and PN 104117 60 for iSteam Contact a MrStea...

Page 19: ...sket The connector is keyed and will only connect in one orientation with the tab facing up LED indicator will light up when the generator is ON Using the CT SteamStop Control The CT SteamStop control...

Page 20: ...meWizard iButler iGenie iSizing iSteam iTempo iTempo Plus Making Wellness a Way of Life Music Therapy Spa Package Steam Genie Steam on Demand Steam Home SmartSizing SteamStart SteamStop SteamTherapy S...

Reviews: