Page 23 of 39
\Table 3 - Temperature Probe Common Resistance Chart
Probe Temp
Maximum Resistance
[
Ω
]
Normal Resistance [
Ω
]
Minimum Resistance [
Ω
]
32°F
(0°C)
27.83
27.28
26.74
77°F
(25°C)
10.1
10
9.9
212°F (100°C)
1
0.97
0.94
11.7
INITIAL STARTUP
After all the checks outlined in the installation section of this manual have been made, the case is ready to be put into
service. Turn on the Power at the breaker box and flip the Power Switch and Light Switch on unit to the on position. Also
ensure that the control is powered on as described above in “Error! Reference source not found.”.
At start up from a warm unit, it is recommended that the temperature control is set to a warmer setting, such as 1. After
the unit has gone through several cycles, adjust the control to a mid-range setting, then to a colder setting if necessary to
maintain desired product temperature
NOTICE:
This refrigerated display case is designed to operate in a maximum environment of 75°F (23.9°C)
and 55% relative humidity. Exceeding these limits will cause poor case performance and excessive
sweating.
11.8
PLACING PRODUCT IN CASE
•
Do not exceed weight limits shown in the table below when loading product into the display case.
Table 4 - Shelf Loading Limits
Model
Top Shelf
Middle Shelf
Bottom Shelf
Display Deck
SSRPF/VS36
80lbs (36kg)
100lbs (45kg)
120lbs (55kg)
165lbs (75kg)
SSRPF/VS50
120lbs (55kg)
140lbs (64kg)
170lbs (77kg)
240lbs (109kg)
SSRPF/VS59
140lbs (64kg)
170lbs (77kg)
210lbs (95kg)
290lbs (132kg)
SSRPF/VS77
180lbs (82kg)
230lbs (105kg)
270lbs (123kg)
390lbs (177kg)
•
Determine desired shelving location before placing product in case. Product must be removed to readjust shelf
location and angle.
•
Do not overhang the front or rear of shelves with product. Improper clearance in front and rear of shelf will block
the refrigerated air flow and will cause product loss.
•
Do not block the slots along the front and rear air discharge slots. Covering these slots will block the refrigerated
air flow and will cause product loss.
•
The display deck is removable for cleaning and can become dislodged in shipment. To ensure proper airflow and
performance of the case, make sure that the display deck is pushed completely down into the plastic evaporator
tub.
•
Allow refrigerated models to run for at least two hours before placing pre-chilled product into unit.
NOTICE:
Case must be stocked with pre-chilled product only. Product should be at or below 40°F (4.5°C)
before adding it to the display case. Use a refrigerator to pull down product that is above 40°F
(4.5°C). This display case is a temperature holding product only. It will not pull down product that
is above the recommended temperature.