background image

Series ’90 Hot Deli

 

 

Page 

6

 

 

DANGER: 

Electrical shock hazard.  Do not operate unit with 
panels removed. 

Grill Removal

 

 
 
 
 

The front of the case has a removable panel base to access the front leg levelers from inside the case.  
Normally it is not necessary to remove the panel to install the case.  The panel must be in place for proper 
operation of the case. 
 
The rear of the case has a removable base panel to allow access to the field wiring connection box.  Remove 
the panel to make field wiring connections.  The panel must be in place for proper operation of the case. 
 

 

Plumbing Connections 

The case is supplied with a 1/2” female NPT pipe coupling and a 1” male NPT drain fitting that can be used 
for a connection to a water source and drain.  A pan filler spray hose is also provided.  This spray hose has a 
1/2" male NPT fitting for connection to a water supply.  If the case is hooked to a water source, it is advisable 
to install a shut-off valve in the water supply line. 
 
Plumbing connections do not have to be made up in order for the case to operate properly.  The well(s) can 
be manually filled to the correct level and they can be drained with the use of a catch container. 

 

Display Component Check 

The case is supplied with incandescent lighting.  The lights are mounted on the ceiling of the case.  The 
control switch for the lights is located on the control panel on the back of the case.  The lights should be 
turned off any time the case is not in operation. 
 
The case is also equipped with a top mounted full-length infrared heater.  The heater temperature control is 
on the control panel on the back of the case.  The temperature control knob has an “off” position and 
numbered positions from 1 to 7 depending on the amount of heating required.  There is a pilot indicator 
above the temperature control knob that lights when the knob is moved to a numbered position.  After the 
case is properly wired to the power source, the temperature control knob should be moved to a numbered 
position to verify that the heater functions properly.  The pilot light indicator will remain lit until the heater 
reaches the proper temperature.  The heater temperature control knob should be in the “off” position any 
time the case is not in operation. 
 
The case has separate temperature controls for each well in the control panel.  The temperature control 
knobs have an “off” position and numbered positions from 1 to 10 depending upon the amount of heating 
required for each well.  There is a pilot light indicator next to each temperature control knob that lights 
when the knob is moved to a numbered position.  After the case is properly wired to the power source, each 
temperature control knob should be moved to a numbered position to verify each well is heating.  This check 
should be performed on one well at a time.  The pilot light indicator will remain lit until the well reaches 
proper temperature.  The temperature control knobs should be in the “off” position when the case is not in 
use. 
 
The case is provided with an air circulation fan to prevent condensation from forming on the front glass 
when water is used in the food wells.  A switch is provided for the fan and is located on the control panel. 

 

Cleaning 

 

The case should be cleaned thoroughly before initial use. 

 
 

For initial setup, clean the case as outlined in the cleaning section. 

Summary of Contents for SN4HD

Page 1: ...ION OPERATION INSTRUCTIONS KEEP THIS MANUAL FOR FUTURE REFERENCE Engineering and technical data are subject to change without notice FEDERAL INDUSTRIES 215 Federal Avenue Belleville WI 53508 Toll Free...

Page 2: ...HECK 6 CLEANING 6 ELECTRICAL INFORMATION GROUNDING 7 OPERATING INSTRUCTIONS 8 INITIAL START UP 8 OPERATING GUIDELINES 8 OPEATION OF WELLS 8 TEMPERATURE CONTROL ADJUSTMENT 9 REAR WRAPPING BOARD 9 LIGHT...

Page 3: ...Federal Industries display case This manual contains important instructions for installing and servicing the Series 90 Hot Deli Cases A repair parts list and wiring diagram are also included in this...

Page 4: ...bel is located on the back of the display case This label is located on the back of the display case This label is located below the control panel on the back of the display case This label is located...

Page 5: ...inspector from the truck line INSTALLATION INSTRUCTIONS Removing Case from Shipping Skid Move the case as near as possible to the final location before removing it from the shipping skid Remove the f...

Page 6: ...l is on the control panel on the back of the case The temperature control knob has an off position and numbered positions from 1 to 7 depending on the amount of heating required There is a pilot indic...

Page 7: ...separate circuit for each display case is recommended to prevent other appliances on the same circuit from overloading the circuit and causing malfunction The electrical service must be grounded upon...

Page 8: ...products at the proper temperature without the use of water The type of food product being kept in the case is the determining factor as to whether water is used in the well Any product that can be ru...

Page 9: ...possible number that will maintain proper product temperature The pilot light will go off when the heater reaches the set temperature Rear Wrapping Board The rear wrapping board is attached to the bac...

Page 10: ...case interior Pneumatic cylinders assist in lifting the glass The glass will hold in any position beyond approximately the first 20 of travel In the first 20 of travel the glass will gently close See...

Page 11: ...e display with a probed temperature of less than 170F if you are using a wet well make sure that the bottom of the deli pan containing the product touches the preheated water in the well Unit Shutdown...

Page 12: ...then outward Clean all foreign material from the door tracks daily Buildup of crumbs may make doors slide hard A light film of lubricant such as PAM can be applied to the tracks to make the doors slid...

Page 13: ...Requests ALL Technical Support please contact Phone 800 356 4206 and choose the Tech Support Warranty Option Email Service federalind com For Warranty Compressors please contact the Parts Department...

Page 14: ...power supply b Check for tripped breaker or blown fuse c Check that the temperature controls are on 2 Lights Do Not Operate a Check that the light switch is on b Check that bulbs are properly seated...

Page 15: ...neral area of the case Any case malfunction or housekeeping problem that creates a slip fall hazard around or under a case should be corrected immediately SALE DISPOSAL Owner Responsibility If you sel...

Page 16: ...ire SN6HD 8AWG Copper Wire The case must also be wired to a 115 VAC single phase three wire electrical source for the general purpose receptacle Units are intended for permanent field connection only...

Page 17: ...8 Pilot Light 42 31607 42 31607 Misc Components Thermometer 41 34007 41 34007 Front Glass 51 10995 50 10998 Clear End Glass 50 11115 50 11115 Reflective End L H 50 11173 50 11173 Reflective End R H 50...

Page 18: ...Series 90 Hot Deli Page 18 WIRING DIAGRAM SN4HD...

Page 19: ...Series 90 Hot Deli Page 19 WIRING DIAGRAM SN6HD...

Page 20: ...Residents Only WARNING This product can expose you to chemicals including chromium which is known to the State of California to cause cancer and birth defects or other reproductive harm For more info...

Page 21: ...Series 90 Hot Deli Page 21 REV CHANGE RECORD APP D DATE ECN...

Reviews: