background image

Series ’90 Hot Deli

 

 

Page 

3

 

 

NOTICE 

 
Read this manual before installing your case.  Keep this manual and refer to it before doing any 
service on the equipment.  Failure to do so could result in personal injury or damage to the case. 
 

NOTICE 

 

Installation and service of the electrical components in the case must be performed by a licensed 
electrician. 

 
The portions of this manual covering electrical components contain technical instructions intended only 
for persons qualified to perform electrical work. 

DANGER   

 

Improper or faulty hookup of electrical components in the case can result in severe injury or 
death. 
 
All electrical wiring hookups must be done in accordance with all applicable local, regional, or 
national standards. 

INTRODUCTION 
 

Thank you for purchasing a Federal Industries display case.  This manual contains important instructions 
for installing and servicing the Series ’90 Hot Deli Cases.  A repair parts list and wiring diagram are also 
included in this manual.  Read all of these documents carefully before installing or servicing your case. 

 
 
 
 
 
 

 
 
 
 
 
 
 

 
 
 
 
 
 
 

 

REGISTRATION & SERIAL NUMBER 

 

It’s important to keep a record of the model and serial number of your merchandiser for warranty and part 
identification.  Please write them here for your quick reference. 
 

Register your product online!

   Visit our website a

www.federalindustries.com

 and register your product 

today. 
 
 

Case Model ________________________________Serial Number_______________________________ 

 
We’re here to provide you with the best possible experience with your new product, however, we cannot cover 
everything about your merchandiser in this manual, so if you have any additional questions or issues, please see 
the SERVICE INFORMATION PAGE to find who you should contact. 
 

 

Summary of Contents for SN4HD

Page 1: ...ION OPERATION INSTRUCTIONS KEEP THIS MANUAL FOR FUTURE REFERENCE Engineering and technical data are subject to change without notice FEDERAL INDUSTRIES 215 Federal Avenue Belleville WI 53508 Toll Free...

Page 2: ...HECK 6 CLEANING 6 ELECTRICAL INFORMATION GROUNDING 7 OPERATING INSTRUCTIONS 8 INITIAL START UP 8 OPERATING GUIDELINES 8 OPEATION OF WELLS 8 TEMPERATURE CONTROL ADJUSTMENT 9 REAR WRAPPING BOARD 9 LIGHT...

Page 3: ...Federal Industries display case This manual contains important instructions for installing and servicing the Series 90 Hot Deli Cases A repair parts list and wiring diagram are also included in this...

Page 4: ...bel is located on the back of the display case This label is located on the back of the display case This label is located below the control panel on the back of the display case This label is located...

Page 5: ...inspector from the truck line INSTALLATION INSTRUCTIONS Removing Case from Shipping Skid Move the case as near as possible to the final location before removing it from the shipping skid Remove the f...

Page 6: ...l is on the control panel on the back of the case The temperature control knob has an off position and numbered positions from 1 to 7 depending on the amount of heating required There is a pilot indic...

Page 7: ...separate circuit for each display case is recommended to prevent other appliances on the same circuit from overloading the circuit and causing malfunction The electrical service must be grounded upon...

Page 8: ...products at the proper temperature without the use of water The type of food product being kept in the case is the determining factor as to whether water is used in the well Any product that can be ru...

Page 9: ...possible number that will maintain proper product temperature The pilot light will go off when the heater reaches the set temperature Rear Wrapping Board The rear wrapping board is attached to the bac...

Page 10: ...case interior Pneumatic cylinders assist in lifting the glass The glass will hold in any position beyond approximately the first 20 of travel In the first 20 of travel the glass will gently close See...

Page 11: ...e display with a probed temperature of less than 170F if you are using a wet well make sure that the bottom of the deli pan containing the product touches the preheated water in the well Unit Shutdown...

Page 12: ...then outward Clean all foreign material from the door tracks daily Buildup of crumbs may make doors slide hard A light film of lubricant such as PAM can be applied to the tracks to make the doors slid...

Page 13: ...Requests ALL Technical Support please contact Phone 800 356 4206 and choose the Tech Support Warranty Option Email Service federalind com For Warranty Compressors please contact the Parts Department...

Page 14: ...power supply b Check for tripped breaker or blown fuse c Check that the temperature controls are on 2 Lights Do Not Operate a Check that the light switch is on b Check that bulbs are properly seated...

Page 15: ...neral area of the case Any case malfunction or housekeeping problem that creates a slip fall hazard around or under a case should be corrected immediately SALE DISPOSAL Owner Responsibility If you sel...

Page 16: ...ire SN6HD 8AWG Copper Wire The case must also be wired to a 115 VAC single phase three wire electrical source for the general purpose receptacle Units are intended for permanent field connection only...

Page 17: ...8 Pilot Light 42 31607 42 31607 Misc Components Thermometer 41 34007 41 34007 Front Glass 51 10995 50 10998 Clear End Glass 50 11115 50 11115 Reflective End L H 50 11173 50 11173 Reflective End R H 50...

Page 18: ...Series 90 Hot Deli Page 18 WIRING DIAGRAM SN4HD...

Page 19: ...Series 90 Hot Deli Page 19 WIRING DIAGRAM SN6HD...

Page 20: ...Residents Only WARNING This product can expose you to chemicals including chromium which is known to the State of California to cause cancer and birth defects or other reproductive harm For more info...

Page 21: ...Series 90 Hot Deli Page 21 REV CHANGE RECORD APP D DATE ECN...

Reviews: