If equipped, check that condensate pan or pump is properly plugged in or
hardwired to power
.
If the pump is running, but cannot evacuate to water,
clean the condensate pump impeller, drain tube and discharge tubing or
replace pump assembly as required.
Note: Owner Responsibility
Pump and deck may be removed from tank by pushing tabs located on tank
sides away from the deck while lifting on pump cover.
Periodically inspect the condensate pump tank to assure it is free of
accumulated dirt or sludge.
DO NOT
use solvent cleaners. Clean tank with
soap and warm water only.
Check valve may be removed for cleaning or replacement by unscrewing with
a 9/16” wrench. Clean Inlet and outlet piping. Reassemble system and check
for correct operation.
Floor Drain
Note: Owner Responsibility
If used, a customer supplied floor drain can become plugged with algae and
debris, which would fall under lack of maintenance and will not be covered
under warranty as it is not part of the unit.
CONDITION
HOT DELI – Water on the Floor
Water On The Floor
Caution!
Water on flooring can not only cause damage, but can also create
a slip hazard. Until properly diagnosed and repaired, be sure to follow these
procedures:
•
Use of a wet-dry shop vacuum is recommended to remove excess water
from both the floor and
condensate pan as well as the interior of the unit’s
base.
•
Water in the condensate pan may be extremely hot if the pan is working
properly and cannot keep up
.
Personal Protection Equipment such as gloves
and long sleeves must be used when emptying the condensate pan to avoid
injury.
Caution!
During a power failure, the condensate pan may overflow and
cause damage and a slip hazard! Restore power as soon as possible. Until
such time that power is restored, follow the steps above.
Plumbing To Unit
If equipped, check water line and connection for the auto-fill humidity pan.
Humidity Pan Below the Wells
Check the placement of the humidity pan, which is located underneath the
interior display deck for proper positioning or potentially missing from being
removed during cleaning.
Drain
The unit has a drain located beneath the interior display deck. The case is not
designed to hold water outside of the humidity pan, and should only drain
spills into a user-supplied bucket to be place inside the base of the unit.
WARNING: DO NOT ATTEMPT TO FILL INTERIOR PAN WITH WATER AS
– INTERIOR OF UNIT IS NOT SUBMERSIBLE AND ELECTRIC SHOCK
AND / OR UNIT DAMAGE CAN OCCUR
.
39