If equipped, check that condensate pan or pump is properly plugged in or
hardwired to power
.
If the pump is running, but cannot evacuate to water,
clean the condensate pump impeller, drain tube and discharge tubing or
replace pump assembly as required.
Note: Owner Responsibility
Pump and deck may be removed from tank by pushing tabs located on tank
sides away from the deck while lifting on pump cover.
Periodically inspect the condensate pump tank to assure it is free of
accumulated dirt or sludge.
DO NOT
use solvent cleaners. Clean tank with
soap and warm water only. Check valve may be removed for cleaning or
replacement by unscrewing with a 9/16” wrench. Clean Inlet and outlet
piping. Reassemble system and check for correct operation.
New Bakery & Series 90 Hot Deli
Only
Each hot well has a manual ball valve to drain each individual well and may
be individually emptied by placing a catch containers under the desired valve
outlet. The Series 90 may also have a drain trough that directs all drain
water to a single hose / floor drain.
Caution:
Allow water to cool in well before draining to prevent burns.