If you sell or give away your Federal Industries case and you evacuate the refrigerant charge before
shipment, Federal Industries recommends that the charge be evacuated into a recovery system to
prevent the possibility of HCFC’s from being released into the atmosphere. The release of these
HCFC’s is a potential source of ozone depletion.
REFRIGERATION & ELECTRICAL DATA
SELF-CONTAINED MODELS
SN4CD
SN6CD
SN8CD
Refrigerant Charge (R-22)
2 lbs.
3 lbs.
3.5 lbs.
ALL MODELS ARE 115 VOLT, 1 PHASE, 60 HERTZ, 2 WIRE
AMPS
AMPS
AMPS
Compressor
RLA
8.6
8.6
13.0
LRA
48.0
48.0
66.3
Condenser Fan Motor
0.6
0.6
1.7
Evaporator Fan Motor (2)
0.5 ea.
0.5 ea.
0.5 ea.
Anti-Fogging Fan Motor (2)
0.5 ea.
0.5 ea.
0.5 ea.
Lights
1.2
1.3
1.7
Condensate Evaporator
1.6
1.6
1.6
Refer to the rating plate data attached to the rear of the case for Maximum Fuse Size and Minimum Circuit
Ampacity.
Each Model is equipped with a general purpose receptacle, requiring a separate electrical circuit of 120V,
15Amps. This circuit must be wired in accordance with the National Electric Code.