Informer Wall Mount Series
13
Installation Instructions
NOTE
: Ensure the screws are placed into material that can adequately support the
weight of the Informer and that the screws are tightened sufficiently to securely
fasten the unit to the stud.
6. Mount the local rubber antenna vertically on the front of the Informer so that the
antenna is pointed toward the ceiling. If you require an external antenna, have it
installed by a qualified electrician in accordance with local and national electrical
codes.
Input/Output Connections
Do not exceed the electrical ratings defined in the specifications for the
Input/Output option.
The Informer has a 600 Ohm balanced audio output and two SPDT relay outputs. A
removable eight (8) position connector is located on the inside of the Informer for
making electrical connections. The connector accepts five (5) mm (3/16 inch)
stripped wire, 18 -26 AWG. Refer to the “Input/Output Definitions” section for
location of parts.
Make electrical connections to the Input/Output connector as follows:
Table 9 Audio/Relay Output
– Input/Output Connections
PIN
DESCRIPTION
1
Audio Output
2
Audio Output
3
Relay 1 N.O. Contact
4
Relay 1 Common
5
Relay 1 N.C. Contact
6
Relay 2 N.O. Contact (used by Strobe)
7
Relay 2 Common (used by Strobe)
8
Relay 2 N.C. Contact
Wiring the Device
SHOCK HAZARD
– To reduce the risk of electric shock, disconnect AC
power before connecting or removing AC power wires. Failure to heed
this warning may cause serious injury or death.
1. Install this device by a qualified electrician in accordance with local and national
electrical codes (NEC/CEC).
2. Make the supply connections directly to the terminal 3-postion terminal block
located internally on the back wall of the housing. The Informer has a universal
input that can be connected to a 115 V line and neutral or two 115 V lines.
Summary of Contents for Informer I-HIOW