background image

12

Federal Signal

 signaling.fedsig.com

Failure to conduct a compatibility check per the guidelines listed below may lead to property damage, serious injury, 

or death.

Models with no LED

• 

Standby Mode Impedance: Equal to the EOL Resistor value (no EOL Resistor equals infinite Ω). 

• 

Alarm Mode Impedance: Equal to the Series Resistor value (no Series Resistor equals 0Ω). 

Models with Factory Provided LED

• 

Standby Mode Impedance: Equal to the EOL Resistor value (no EOL Resistor equals infinite Ω). 

• 

Alarm Mode Impedance: Variable. Based on EOL selected and models rated voltage. Refer to Table 1 below. Models 

with a factory provided LED will contain the following installed LED series resistors: 6 V model: 470 Ω, 12 V model: 

1 KΩ, 24 V: 1.8 KΩ, and 48 V model: 3.3 KΩ. Table 1 takes this additional impedance into account.

 Table 2  Alarm Mode

ALARM MODE NOMINAL IMPEDANCE FOR A CALLPOINT 

WITH LED MODULE

6 V

12 V

24 V

48 V

EO

L RESI

ST

OR

470

235.00

319.73

1000

319.73

500.00

642.86

2200

387.27

687.50

990.00

1320.00

3300

411.41

767.44

1164.71

1650.00

4700

427.27

824.56

1301.54

1938.75

5000

429.62

833.33

1323.53

1987.95

5600

433.61

848.48

1362.16

2076.40

10000

448.90

909.09

1525.42

2481.20

12000

452.29

923.08

1565.22

2588.24

15000

455.72

937.50

1607.14

2704.92

22000

460.17

956.52

1663.87

2869.57

33000

463.40

970.59

1706.90

3000.00

47000

465.35

979.17

1733.61

3083.50

Electrical Specifications

Maximum Input Voltage: 6, 12, 24, or 48 Vdc when LEDs are present; if no LEDs are present, 48 Vdc maximum.

Maximum Input Current: 5 A / 1 A*

*1 A with FS-approved diode installed (See Table 2 on page 23 for the diode part number.)

Before connecting to the power, confirm that the external voltage source and internal EOL/Series resistor values are in 

accordance as shown above. The resistance of the resistor modules are marked on the resistor module enclosures. If 

the EOL/series resistor value chosen is outside the range above, the hazardous area safety protection of the Ex potted 

module is compromised. The maximum power dissipation on the resistor is 1 W. Failure to observe this warning may 

lead to property damage, serious injury, or death.

Maximum Ground Wire: 12 AWG / 2.05 mm

Summary of Contents for CP-PB Series

Page 1: ...stallation test the station and the system to ensure that it is operating properly After testing is complete provide a copy of this instruction sheet to all personnel Establish a procedure to routinel...

Page 2: ...11 certification 3 To enable correct installation and operation review all sections in this manual 25500424A for all technical installation and maintenance data UL C UL Signaling Certification Inform...

Page 3: ...einforced polyester GRP thermoset plastic housing and faceplate for corrosion resistance 40 C to 70 C ambient operational coverage Static dissipative GRP housings and faceplates One or two switches av...

Page 4: ...d 6 V 12 V 24 V or 48 V LED bi color status indicator High impact resistant clear polycarbonate cover flap with or without various instructional labels e g LIFT COVER BREAK GLASS TO ACTIVATE on interi...

Page 5: ...inter Figure 1 Removing the keyway UNLOOSENM4SETSCREW TOREMOVERESET KEYWAYANDBEARING WASHERIFPRESENT UNLOOSENTWOM4 CAPTIVATEDSCREWS REMOVE BUTTON ANDSCREW Figure2 ACTUATORSPRING PIVOTBOSSES CLEAR ACTU...

Page 6: ...Chamber Access All models of the Call Point station have the same rear chamber access method for internal wiring management mounting the unit to a vertical wall surface and general maintenance routin...

Page 7: ...accordance with the installation instructions and local jurisdictions and codes Use installer supplied fasteners suitable for the mounting surface All models of the Call Point station have the same re...

Page 8: ...corrosive environment applications mounting the station to a rigid surface Ensure that all cable glands and stopping plugs are certified with a suitable sealing washer o ring to ensure the NEMA IP ra...

Page 9: ...on the aluminum mounting bracket and remove it from the rear housing taking care as it still remains directly wired to the front housing assembly 2 Strip the incoming wiring leads to the station to t...

Page 10: ...ull double throw switch device on a double pull double throw device input terminals 6 7 and 8 are used as secondary inputs with common Figure 8 Standard SPDT switch wiring Figure 9 Standard DPDT switc...

Page 11: ...tivation current draw of 13 mA of the red alarm state LED function will not interfere with the alarm notification panel If it does the hookup of the red LED lead must be disconnected from the terminat...

Page 12: ...990 00 1320 00 3300 411 41 767 44 1164 71 1650 00 4700 427 27 824 56 1301 54 1938 75 5000 429 62 833 33 1323 53 1987 95 5600 433 61 848 48 1362 16 2076 40 10000 448 90 909 09 1525 42 2481 20 12000 452...

Page 13: ...ATE ACTIVATION INDICATOR STATUS POSITIONS VISUAL ACTIVATION INDICATOR WITH RESET KEYWAY ALARM STATEACTIVATED Reset Test For the manual pushbutton stations resetting is accomplished by rotating the act...

Page 14: ...s resetting is accomplished by either of two methods following the previously mentioned two methods of activating the stations 1 To replace the broken glass panel follow the directions on page 16 Once...

Page 15: ...re some important safety instructions and precautions you should follow with regards to all instructions within this manual Read and understand all instructions before operating this system If you acq...

Page 16: ...this manual to do so Replacing the Break Glass Panel CP BG units To replace a broken glass panel on the station CUTTING HAZARD Safety gloves are required when accessing the internal front chamber with...

Page 17: ...DELS Installing Servicing the Reset Keyway The reset keyway is factory attached on the CP PB and CP BG stations On the CP BG x x x xxx xx 2 E54 11 approved stations it is provided separately to be use...

Page 18: ...ertified models To remove or remove reattach a cover flap 1 Remove the front faceplate per directions found earlier in Call Point Front Chamber Access on page 5 Place the two stainless steel pivot pin...

Page 19: ...es resistor along with two wire ties Tools needed after internal access Wire cutter 1 Philips screwdriver To service the module 1 Ensure that the power is off and the station is in NORMAL mode 2 Open...

Page 20: ...reseat the module in its reliefs screw it in place and try again e After confirming that the station actuates properly use the two wire ties provided within the kit to bundle and tie the switch wires...

Page 21: ...station faceplate s designated label area Make sure the application area is free from any dirt smudges or oil prior to application Figure 31 Installing the label OPTIONALINDIVIDUALSTAINLESSSTEELFACEP...

Page 22: ...ion of hazardous atmospheres disconnect the fixture from the supply circuit before opening EXPLOSION HAZARD Substitution of any component may impair suitability for Class I Division 2 Service Technica...

Page 23: ...used with 24V LED option 2 2K 2200 2 4K 2400 3 3K 3300 also used with 48V LED option 3 6K 3600 4 7K 4700 5 6K 5600 10K 10000 12K 12000 15K 15000 22K 22000 33K 33000 47K 47000 Potted Diode Module 5A K...

Page 24: ...g com signaling fedsig com Part Description Federal Signal Part Use Faceplate Label EN54 11 K71400701A CP BG x x x xxx xx 2 EN54 11 stations Faceplate Label Stainless Steel FIRE K71400976A 01 CP BG an...

Reviews: