background image

9

Specifications

Description, Specifications, Installation, and Operation Manual

 

Federal Signal 

www.fedsig.com

Specifications

Table 3 Specifications

Operating Voltages

9-15 Vdc

108-128 Vac, 60 Hz with wall transformer

Operating Current  

(from wall transformer for I-IP2)

Standby (at 12 Vdc) ≤ 400 mA

Signaling (at 12 Vdc) < 650 mA 

Operating with PoE,

IEEE 802.3af, 48V input 

(for each Informer-PA device)

PoE: 48 Vdc (42 to 57 Vdc), IEEE 802.3af

Standby (at 48 Vdc) < 200 mA

Signaling (at 48 Vdc) < 300 mA

Audio Data

8000 samples/sec, μLaw compression

Audio Data Playback Storage

17 hours and 4,000 messages with 2 GB microSD card 

Audio Frequency response

300-3000 Hz, +1 to -3 dB per octave

Warning Siren Audio

Seven factory-installed siren tones: wail, alternate wail, 

pulsed wail, steady, alternate steady, pulsed steady, and 

Westminster chime (auxiliary)

Serial Port 

RS232C, N, 8, 1 Baud rate configurable

Ethernet Port

IEEE 802.3, 10 BASE-T connection

Operating temp range

-22°F to +140°F (-30°C to + 60°C)

Humidity range

0-95%, non-condensing

Size (H x W x L)

1.7 x 14.0 x 6.1 inches (43.18 x 355.6 x 154.94 mm)

Weight

2.5 lb (1.1 kg) 

Shipping Weight

4 lb (1.8 kg)

Table 4 Compliance

Electromagnetic 

Interference

Complies with FCC Title 47, Part 15

FCC Part 15 

Class B

Radio Frequency Interference (RFI) (FCC 15.105)

The Informer-PA was tested and found to comply with the limits for 

Class B digital devices pursuant to Part 15 Subpart B of the FCC Rules. 

These limits are designed to provide reasonable protection against 

harmful interference in a residential environment. This equipment 

generates, uses, and can radiate radio frequency energy, and if not 

installed and used in accordance with the instruction manual, may 

cause harmful interference to radio communications. However, there is 

no guarantee that interference will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off and on. 

Try to correct the interference by one or more of the following measures: 

•  Increase the separation between the equipment and the receiver.

•  Connect the equipment to a different circuit than the receiver that it 

is connected to.

Electrical Code 

Compliance

Complies with UL 60065 and CAN/CSA Std. C22.2 No. 60065

Summary of Contents for C Series

Page 1: ...0 0820 Printed in U S A Copyright 2019 2020 Federal Signal Corporation Informer PA for Public Address Interface Model I IP2 Series C Dual Rack Wall Mount Description Specifications Installation and Op...

Page 2: ...ederal Signal Drive University Park IL 60484 email to info fedsig com or call 1 708 534 3400 This limited warranty is in lieu of all other warranties express or implied contractual or statutory includ...

Page 3: ...Ordering Information 8 Specifications 9 Installation 10 Determine a Suitable Location 10 Rack Mounting 10 Wall Mounting 11 Memory Card Removal and Installation 12 Testing and Training 13 Operations 1...

Page 4: ...5 Visual Indications 14 Table 6 JP3 Input Output Connections 14 Table 7 J1 Rear Input 14 Table 8 FS232 Connector Pin out 15 Table 9 J2 Input Power 15 Table 10 Replacement Part Numbers 16 Figures Figur...

Page 5: ...ystem regularly to confirm that it will be operational in an emergency Safety Messages to Installers People s lives depend on your safe installation of our products It is important to follow all instr...

Page 6: ...system may not provide the intended audible warning and service personnel may be exposed to death permanent hearing loss or other bodily injury File these instructions in a safe place and refer to the...

Page 7: ...simplifies wide scale deployments The Informer PA provides an unmatched value for indoor alert and notification for schools hospitals police and fire stations government facilities and industrial pla...

Page 8: ...Information Part Numbers Description I IP2 Dual Rack Wall Desk Mount Informer PA I IP IO Informer IP Desk Mount I IPW Informer IP Wall Mount I IP100DC Informer100 24 Vdc 100 watt speaker I IP100AC In...

Page 9: ...1 inches 43 18 x 355 6 x 154 94 mm Weight 2 5 lb 1 1 kg Shipping Weight 4 lb 1 8 kg Table 4 Compliance Electromagnetic Interference Complies with FCC Title 47 Part 15 FCC Part 15 Class B Radio Frequen...

Page 10: ...Suitable Location When choosing a location for the Informer PA consider the following criteria Place as far as possible from electrically noisy electronic devices to avoid interference Examples of no...

Page 11: ...f the cord into the power jack located at the rear of the Informer PA Route the cord to ensure it is protected against walking on tripping over or pinching the cord Wall Mounting The Informer PA can a...

Page 12: ...into the power jack located at the rear of the Informer PA Route the cord to ensure it is protected against walking on tripping over or pinching the cord Memory Card Removal and Installation The micro...

Page 13: ...the emergency operating plan Alerts should exceed the ambient sound levels by at least 10 dB to ensure they can be heard Conduct testing regularly per facility safety plans to ensure the equipment rem...

Page 14: ...of the Informer PA for making electrical connections The connector accepts 3 16 inch 5 mm stripped wire 18 26 AWG The output level is adjustable from 0 to 2 5 VP P into 600 ohms with a 1 kHz tone Eac...

Page 15: ...mer PA has an eight pin Ethernet port for connecting to the Communications network The port accepts 42 to 57 Vdc PoE per IEEE 802 3af Ethernet wire runs must be less than 328 feet 100 meters from the...

Page 16: ...he picture below and order the corresponding part number Table 10 Replacement Part Numbers Picture Part Number 13900406A 08 140372A 08 Getting Service If you are experiencing any difficulties contact...

Reviews: