background image

5

Safety Messages

Description, Specifications, Installation, and Operation Manual

 

Federal Signal 

www.fedsig.com

Safety Messages

It is important to follow all instructions shipped with this product. This device is to be installed 

by trained personnel who are thoroughly familiar with the country electric codes and will follow 

these guidelines as well as local codes and ordinances, including any state or local noise control 

ordinances. Listed below are important safety instructions and precautions you should follow:

Planning

•  If suitable warning equipment is not selected, the installation site for the Informer is not 

selected properly or the Informer is not installed properly, it may not produce the intended 

optimum audible warning. If applicable, follow Federal Emergency Management Agency 

(FEMA) recommendations. 

•  If the Informer is not activated in a timely manner when an emergency condition exists, it 

cannot provide the intended audible warning. It is imperative that knowledgeable people, who 

are provided with the necessary information, be available at all times to authorize activation. 

•  The sound output of the Informer is capable of causing permanent hearing damage. To 

prevent excessive exposure, carefully plan placement, post warnings, and restrict access to 

areas near sirens. 

•  Activating the Informer may not result in people taking the desired actions if those to be 

warned are not properly trained about the meaning of warning sounds. Users should follow 

FEMA recommendations and instruct those to be warned of correct actions to be taken.

After installation, service, or maintenance, test the system to confirm that it is operating properly. 

Test the system regularly to confirm that it will be operational in an emergency. 

Safety Messages to Installers

People’s lives depend on your safe installation of our products. It is important to follow all 

instructions shipped with this product. This device is to be installed by a trained electrician who 

is thoroughly familiar with the National Electrical Code and/or Canadian Electrical Code and will 

follow the NEC and/or CEC Guidelines as well as all local codes. 

The selection of the mounting location for this Informer, its controls and the routing of the wiring 

are to be accomplished under the direction of the Facilities Engineer and the Safety Engineer. 

Listed below are some other important safety instructions and precautions you should follow:

•  Electrocution or severe personal injury can occur when performing various installation and 

service functions such as making electrical connections, drilling holes, or lifting equipment. 

Therefore, only experienced electricians should install this product in accordance with national, 

state and any other electrical codes having jurisdiction. Perform all work under the direction of 

the installation or service crew safety foreman.

•  Read and understand all instructions before installing, operating, or servicing this equipment.
•  All effective warning sounds may, in certain circumstances, cause permanent hearing loss. 

Take appropriate precautions such as wearing hearing protection. Maximum sound level 

exposure limits specified in OSHA 29 CFR 1910 should not be exceeded. Review and comply 

with any local or state noise control ordinances as well as OSHA noise exposure regulations 

and guidelines.

•  For optimum sound distribution do not install this speaker where objects would block any 

portion of the front of the Informer. 

•  Establish a procedure to routinely check the signal system for proper activation and operation.

Summary of Contents for C Series

Page 1: ...0 0820 Printed in U S A Copyright 2019 2020 Federal Signal Corporation Informer PA for Public Address Interface Model I IP2 Series C Dual Rack Wall Mount Description Specifications Installation and Op...

Page 2: ...ederal Signal Drive University Park IL 60484 email to info fedsig com or call 1 708 534 3400 This limited warranty is in lieu of all other warranties express or implied contractual or statutory includ...

Page 3: ...Ordering Information 8 Specifications 9 Installation 10 Determine a Suitable Location 10 Rack Mounting 10 Wall Mounting 11 Memory Card Removal and Installation 12 Testing and Training 13 Operations 1...

Page 4: ...5 Visual Indications 14 Table 6 JP3 Input Output Connections 14 Table 7 J1 Rear Input 14 Table 8 FS232 Connector Pin out 15 Table 9 J2 Input Power 15 Table 10 Replacement Part Numbers 16 Figures Figur...

Page 5: ...ystem regularly to confirm that it will be operational in an emergency Safety Messages to Installers People s lives depend on your safe installation of our products It is important to follow all instr...

Page 6: ...system may not provide the intended audible warning and service personnel may be exposed to death permanent hearing loss or other bodily injury File these instructions in a safe place and refer to the...

Page 7: ...simplifies wide scale deployments The Informer PA provides an unmatched value for indoor alert and notification for schools hospitals police and fire stations government facilities and industrial pla...

Page 8: ...Information Part Numbers Description I IP2 Dual Rack Wall Desk Mount Informer PA I IP IO Informer IP Desk Mount I IPW Informer IP Wall Mount I IP100DC Informer100 24 Vdc 100 watt speaker I IP100AC In...

Page 9: ...1 inches 43 18 x 355 6 x 154 94 mm Weight 2 5 lb 1 1 kg Shipping Weight 4 lb 1 8 kg Table 4 Compliance Electromagnetic Interference Complies with FCC Title 47 Part 15 FCC Part 15 Class B Radio Frequen...

Page 10: ...Suitable Location When choosing a location for the Informer PA consider the following criteria Place as far as possible from electrically noisy electronic devices to avoid interference Examples of no...

Page 11: ...f the cord into the power jack located at the rear of the Informer PA Route the cord to ensure it is protected against walking on tripping over or pinching the cord Wall Mounting The Informer PA can a...

Page 12: ...into the power jack located at the rear of the Informer PA Route the cord to ensure it is protected against walking on tripping over or pinching the cord Memory Card Removal and Installation The micro...

Page 13: ...the emergency operating plan Alerts should exceed the ambient sound levels by at least 10 dB to ensure they can be heard Conduct testing regularly per facility safety plans to ensure the equipment rem...

Page 14: ...of the Informer PA for making electrical connections The connector accepts 3 16 inch 5 mm stripped wire 18 26 AWG The output level is adjustable from 0 to 2 5 VP P into 600 ohms with a 1 kHz tone Eac...

Page 15: ...mer PA has an eight pin Ethernet port for connecting to the Communications network The port accepts 42 to 57 Vdc PoE per IEEE 802 3af Ethernet wire runs must be less than 328 feet 100 meters from the...

Page 16: ...he picture below and order the corresponding part number Table 10 Replacement Part Numbers Picture Part Number 13900406A 08 140372A 08 Getting Service If you are experiencing any difficulties contact...

Reviews: