RS232 Port

The RS232 Port uses a six-pin modular connector. Federal Signal can provide pre-

terminated cables when scrolling message displays are purchased. 

Table 8 FS232 Connector Pin-out

Pin Description

1

Serial / Flash Select

2

TXD

3

RXD

4

GND

5

CTS / Serial Clock In

6

RTS

Ethernet Port

The Informer-PA has an eight-pin Ethernet port for connecting to the Communications 

network. The port accepts 42 to 57 Vdc PoE per IEEE 802.3af. Ethernet wire runs must be 

less than 328 feet (100 meters) from the nearest network switch. The wired Ethernet port 

auto-negotiates a 10/100, full or half-duplex connection.  

Power Connector

The Informer-PA can be powered via PoE from the LAN connection. The Informer-PA can 

also be powered from the equipped wall type plug-in external AC/DC power supply. The 

connections for power are in the table.

Table 9 J2 Input Power

J2

Power connector

Center – (9 to 15 Vdc)

Outside – GND

Summary of Contents for C Series

Page 1: ...0 0820 Printed in U S A Copyright 2019 2020 Federal Signal Corporation Informer PA for Public Address Interface Model I IP2 Series C Dual Rack Wall Mount Description Specifications Installation and Op...

Page 2: ...ederal Signal Drive University Park IL 60484 email to info fedsig com or call 1 708 534 3400 This limited warranty is in lieu of all other warranties express or implied contractual or statutory includ...

Page 3: ...Ordering Information 8 Specifications 9 Installation 10 Determine a Suitable Location 10 Rack Mounting 10 Wall Mounting 11 Memory Card Removal and Installation 12 Testing and Training 13 Operations 1...

Page 4: ...5 Visual Indications 14 Table 6 JP3 Input Output Connections 14 Table 7 J1 Rear Input 14 Table 8 FS232 Connector Pin out 15 Table 9 J2 Input Power 15 Table 10 Replacement Part Numbers 16 Figures Figur...

Page 5: ...ystem regularly to confirm that it will be operational in an emergency Safety Messages to Installers People s lives depend on your safe installation of our products It is important to follow all instr...

Page 6: ...system may not provide the intended audible warning and service personnel may be exposed to death permanent hearing loss or other bodily injury File these instructions in a safe place and refer to the...

Page 7: ...simplifies wide scale deployments The Informer PA provides an unmatched value for indoor alert and notification for schools hospitals police and fire stations government facilities and industrial pla...

Page 8: ...Information Part Numbers Description I IP2 Dual Rack Wall Desk Mount Informer PA I IP IO Informer IP Desk Mount I IPW Informer IP Wall Mount I IP100DC Informer100 24 Vdc 100 watt speaker I IP100AC In...

Page 9: ...1 inches 43 18 x 355 6 x 154 94 mm Weight 2 5 lb 1 1 kg Shipping Weight 4 lb 1 8 kg Table 4 Compliance Electromagnetic Interference Complies with FCC Title 47 Part 15 FCC Part 15 Class B Radio Frequen...

Page 10: ...Suitable Location When choosing a location for the Informer PA consider the following criteria Place as far as possible from electrically noisy electronic devices to avoid interference Examples of no...

Page 11: ...f the cord into the power jack located at the rear of the Informer PA Route the cord to ensure it is protected against walking on tripping over or pinching the cord Wall Mounting The Informer PA can a...

Page 12: ...into the power jack located at the rear of the Informer PA Route the cord to ensure it is protected against walking on tripping over or pinching the cord Memory Card Removal and Installation The micro...

Page 13: ...the emergency operating plan Alerts should exceed the ambient sound levels by at least 10 dB to ensure they can be heard Conduct testing regularly per facility safety plans to ensure the equipment rem...

Page 14: ...of the Informer PA for making electrical connections The connector accepts 3 16 inch 5 mm stripped wire 18 26 AWG The output level is adjustable from 0 to 2 5 VP P into 600 ohms with a 1 kHz tone Eac...

Page 15: ...mer PA has an eight pin Ethernet port for connecting to the Communications network The port accepts 42 to 57 Vdc PoE per IEEE 802 3af Ethernet wire runs must be less than 328 feet 100 meters from the...

Page 16: ...he picture below and order the corresponding part number Table 10 Replacement Part Numbers Picture Part Number 13900406A 08 140372A 08 Getting Service If you are experiencing any difficulties contact...

Reviews: