3) Selecting "start to stop" mode
Mode selection screen
Select the target mode of measurement by moving the cursor
with
/
keys.
Confirmation screen
If OK, press the
key.
To go back to Mode selection, press the
key.
Waiting for Run command (Standby for measurement)
Upon receiving Run command, the measurement will start.
If a Run command has already been received, this screen will
be skipped.
Measurement in progress
The measurement will continue until the inverter is stopped.
To discontinue the measurement, press the
key.
Duration
Max. output current
Average output current
Average braking power
[Display of measurement
results]
Figure 3.26 Screen Transition for "Start to Stop" Mode
4) Going back to Running mode
While the measurement of the load factor is in progress, you can go back to the running mode by
pressing the
key (or, to the Mode selection screen by pressing the
key).
In these cases, the measurement of the load factor will continue. You can go back to "9. LOAD
FCTR" and confirm, on the Mode selection screen, that the measurement is in progress.
After the measurement has ended, you can view the results of the measurement by pressing the
key on the Mode selection screen.
When the alarm occurs or the inverter power is turned off, the measurement result is
cleared.
Press the
key to signal "Ready."
Run com. ON
Measurement will start upon receiving Run command.
Measurement will stop when the inverter is stopped or you
press the
Stopped /
key.
To return to Mode selection, press the
key.