![Fbt DLM26 User Manual Download Page 38](http://html.mh-extra.com/html/fbt/dlm26/dlm26_user-manual_547126038.webp)
EQ Byp page
– from this sub-menu it is possible to Bypass or to make active the 5 Bands
Equalizer placed on the Output Signal Path.
When Bypassed the 5 Bands Equalizer, its current setting will not be lost.
EQ: [x] sub-menu
– from this sub-menu it is possible to set the Output Channels five available
Multi-Type Filters.
Anyone of the 5 filters of the Eq can be selected hosing from the list of filter types shown already
at the “Input Path” section
[Peaking_Eq, Hi-Shelv_1, Hi-Shelv_2, Hi-Shelv_Q, Lo-Shelv_1, Lo-Shelv_2, Lo-
Shelv_Q, Low Pass_1, Low Pass_2, Low Pass_Q, High Pass_1, High Pass_2, High Pass_Q, All Pass_1, All
Pass_2, Band Pass, Notch Filt]
More, the DLM26 Is giving the possibility to “Bypass” any single filter of the 5 available in the Equalizer
section; Once in the editing page of the single filter, a “Byp” field is available for making the single filter
active or not
Pushing the Enter Button, the above window will allow the access to the “Byp” and “Type” fields.
Using the Param.2 encoder, the selected Filter can be activated or bypassed.
The DLM26 allows the user to select anyone of the filter's type listed above and assign them
independently using the 5 available filters.
In order to select the filter's type, it is necessary to use the Param.3 encoder, rotate it “clockwise”
or “counter-clockwise” to select the desired filter.
So, in order to define the filter type for the filter number 1 (“x”=1), it is necessary from the above
screen, to select the filter, which name will appear on the screen.
If selected a Peaking_Eq filter, then the display will be as follow:
Once selected the desired Filter Type, its parameters can be accessed for editing just pressing
again the ENTER Button.
Once pressed the ENTER Button, the editing page of the selected filter type will be accessed ONLY
if the selected filter it is not set in Bypass mode.
Depending from the selected filter, the related parameters will be available for editing
Out-1 Name EQ-1
->Byp=Off Type=Peaking_Eq
Out-1 Name EQ-X
Byp=Off Type=Peaking_Eq
Out-1 Name EQ Byp
Eq Bypass = Off
Out-1 Name EQ-X
->Byp=Off Type=Peaking_Eq