![FBII XL-4 Installation And Setup Manual Download Page 46](http://html1.mh-extra.com/html/fbii/xl-4/xl-4_installation-and-setup-manual_3747328046.webp)
Xl-4, XL-4B, and XL-5 Hookup and Installation Instructions
Version 4
5–18
programmed (daily, monthly, weekly, # events). Note: To obtain a printout after each event,
program the number of events to 1.
The local printer at the control panel location must have the following characteristics: Serial
printer, 300 baud, 8 data bits, one stop bit, and no parity.
Keypad Function Summary
End User Functions
PROCEDURE
KEY SEQUENCE
ARM SYSTEM
[USER]
STAY
STAY [USER]
INSTANT
INSTANT [USER]
INSTANT-STAY
INSTANT STAY [USER] or STAY INSTANT [USER]
BYPASS
BYPASS [USER] [ZN]
GROUP BYPASS
BYPASS [USER]
✴
1 [ZN]
BYPASS multiple
BYPASS [USER] [ZN] BYPASS [ZN] BYPASS [ZN] ......
UNBYPASS
BYPASS [USER] [ZN]
UNBYPASS multiple
BYPASS [USER] [ZN] BYPASS [ZN] BYPASS [ZN] ......
GROUP UNBYPASS
BYPASS [USER]
✴
2 [ZN]
FORCED ARMING
BYPASS [USER] BYPASS
DISARM
[USER]
USER DEFINITION
CODE[USER][US#][USID][LEV]
MULTI-PARTITION
# 0 [USER] p 0=Arm all partitions, 9=Disarm all
QUICK ARM
# 1
QUICK FORCED ARM
# 2
TIME DATE Set
# 3
ZONE DIRECTORY
# 4 [NOTE: LCD Keypads Only]
QUICK BYPASS
# 5 ZN
CHIME MODE
# 6
USER PART. ASSIGNMENT # 7 [USER]
Installer Functions
PROCEDURE
KEY SEQUENCE
KEYPAD PROGRAMMING
CODE
✴
[INSTALLER CODE] 1
TIME/DATE SETUP
CODE
✴
[INSTALLER CODE] 2
WALK TEST w/o BELL†
CODE
✴
[INSTALLER CODE] 3
WALK TEST with BELL†
CODE
✴
[INSTALLER CODE] 4
DEFAULT RESET
CODE
✴
[INSTALLER CODE] 5
SYSTEM LOG VIEW
CODE
✴
[INSTALLER CODE] 6
† = LCD KEYPADS ONLY
Keypad programming is exited by
✴
and #, all other functions are exitied by the
✴
alone.