Xl-4, XL-4B, and XL-5 Hookup and Installation Instructions
Version 4
3–10
If this control panel will be used for uploading, downloading or remote command applications, the
telephone line connected to the control panel must not be shared with a fax machine or modem
.
Tamper Switch
For UL Mercantile installations the circuit board enclosure (panel model XL-4B) MUST be
tampered. Three mounting holes are provided on the right hand side of the enclosure to
install the tamper switch. (AMSECO ATS-1, or ADEMCO No.19) Refer to UL Standard 681
for further information.
Relay #1
Relay #1 can be used as a bell output or as dry contacts as shown below:
Bell Output
UL commercial installations require ADEMCO model AD10-12 or ADEMCO MBL-8 mounted
in the model AB bell housing. Maximum alarm load is 1 Amp.
REFER TO WIRING DIAGRAMS FOR FURTHER DETAILS
Connections To FBII Siren Drivers
Control
679
VS279
VS299
Panel Siren Driver Voice Siren Driver Voice Siren Driver
28 (Bell)
1
1
2
30(-)
2
3
7
31 (Const. Power)
N/A
4
6
NOTES FOR VS279 & VS299
Burglary message requires Relay 1 programmed for latched operation. Fire message
requires relay 1 programmed for pulsed operation.
Consult the Installation Instructions of the siren drivers for additional information.
Dry Contacts
Contacts rated 110 VAC, 24 VDC, 3 Amps.
28
26
12 v
BELL
SET UP AS BELL OUTPUT JP2 CONNECTED
27
29
28
SET UP AS DRY CONTACTS JP2 CUT
NORMALLY OPEN
COMMON
NORMALLY CLOSED