Maintenance measures - 250 h
4812159701_D.pdf
2021-03-16
Battery
- Check condition
Figure. Batteries
The batteries are sealed and maintenance-free.
Make sure there is no open flame in the vicinity
when checking the electrolyte level. Explosive gas
is formed when the alternator charges the battery.
Make sure there is no open flame in the vicinity
when checking the electrolyte level. Explosive gas
is formed when the alternator charges the battery.
When disconnecting the battery, always
disconnect the negative cable first. When
connecting the battery, always connect the
positive cable first.
When disconnecting the battery, always
disconnect the negative cable first. When
connecting the battery, always connect the
positive cable first.
The cable shoes should be clean and tightened.
Corroded cable shoes should be cleaned and greased
with acid-proof Vaseline.
Wipe the top of the battery.
Air conditioning (Optional)
- Inspection
Fig. Air conditioning
1. Refrigerant hoses
2. Condensor element
3. Drying filter
2
3
1
Inspect refrigerant hoses and connections and make
sure that there are no signs of an oil film that can
indicate a refrigerant leakage.
If there is a signifcant loss of cooling capacity, clean
the condensor element (2) on the rear edge of the cab
roof.
119
Summary of Contents for DYNAPAC CC224C
Page 2: ......
Page 16: ...Introduction 4812159701_D pdf 2021 03 16 4...
Page 26: ...Special instructions 4812159701_D pdf 2021 03 16 14...
Page 90: ...Operation 4812159701_D pdf 2021 03 16 78...
Page 104: ...Preventive maintenance 4812159701_D pdf 2021 03 16 92...
Page 124: ...Maintenance 10h 4812159701_D pdf 2021 03 16 112...
Page 128: ...Maintenance 50h 4812159701_D pdf 2021 03 16 116...
Page 168: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...