Machine description
4812159201_F.pdf
2019-10-21
"CALIBRATION"
- service personnel only, requires
password.
"EDC Calibration" used to calibrate the joystick and
speed potentiometer.
"TX Program" only used to change software in the
display and requires special equipment and know-how.
"EDC CALIBRATION"
To calibrate, move the joystick fully forward (F) and
press in both black buttons on the top of the joystick.
(See also manual W3025)
Continue in the same way with the other positions for
the joystick (N), (R) and the speed potentiometer.
Press the disk button to save the values.
"ABOUT"
It is also possible to see the version of the installed
software.
44
Summary of Contents for DYNAPAC CA1500
Page 2: ......
Page 12: ...e 4812159201_F pdf 2019 10 21...
Page 16: ...Introduction 4812159201_F pdf 2019 10 21 4...
Page 22: ...Safety Optional 4812159201_F pdf 2019 10 21 10...
Page 26: ...Special instructions 4812159201_F pdf 2019 10 21 14...
Page 68: ...Machine description 4812159201_F pdf 2019 10 21 56...
Page 88: ...Operation 4812159201_F pdf 2019 10 21 76...
Page 98: ...Operating instructions Summary 4812159201_F pdf 2019 10 21 86...
Page 100: ...Operating instructions Summary 4812159201_F pdf 2019 10 21 88...
Page 102: ...Preventive maintenance 4812159201_F pdf 2019 10 21 90...
Page 106: ...Maintenance Lubricants and symbols 4812159201_F pdf 2019 10 21 94...
Page 118: ...Maintenance 10h 4812159201_F pdf 2019 10 21 106...
Page 124: ...Maintenance 50h 4812159201_F pdf 2019 10 21 112...
Page 140: ...Maintenance measures 500 h 4812159201_F pdf 2019 10 21 128...
Page 152: ...Maintenance 1000h 4812159201_F pdf 2019 10 21 140...
Page 167: ......
Page 168: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...