Maintenance - 2000h
4812159201_F.pdf
2019-10-21
Fuel tank - Draining (Optional)
Fig. Machine's right underside
1. Drain plug
2. Drain cock
1
2
Water and sediment in the fuel tank are removed via
the drainage plug in the bottom of the fuel tank.
Be very careful during draining. Do not drop the
plug or else all the fuel will flow out.
Be very careful during draining. Do not drop the
plug or else all the fuel will flow out.
Drain the roller after it has been stationary for a long
time, e.g. after standing overnight. The fuel level
should be as low as possible.
The roller should preferably have been standing with
this side somewhat lower, so that water and sediment
will gather near the drainage plug (1). Drain as follows:
Place a container under the plug (1).
Loosen the drain plug (1). Then open the drain cock
(2) and drain out water and sediment until only pure
diesel fuel emerges at the plug. Close the drain cock
and screw in the plug again.
Air conditioning (Optional)
Fresh air filter - Change
Fig. Cab
1. Fresh air filter (x 2)
2. Screws (x 3)
1
2
2
Use a step ladder to reach the filter (1). The filter
can also be accessed via the right cab window.
Use a step ladder to reach the filter (1). The filter
can also be accessed via the right cab window.
There is a fresh air filter (1), located at the front of the
cab.
Undo the three screws (2) and remove the protective
cover.
Remove the two air filter inserts and replace with new
ones.
It may be necessary to change the filters more often if
the machine is working in a dusty environment.
153
Summary of Contents for DYNAPAC CA1500
Page 2: ......
Page 12: ...e 4812159201_F pdf 2019 10 21...
Page 16: ...Introduction 4812159201_F pdf 2019 10 21 4...
Page 22: ...Safety Optional 4812159201_F pdf 2019 10 21 10...
Page 26: ...Special instructions 4812159201_F pdf 2019 10 21 14...
Page 68: ...Machine description 4812159201_F pdf 2019 10 21 56...
Page 88: ...Operation 4812159201_F pdf 2019 10 21 76...
Page 98: ...Operating instructions Summary 4812159201_F pdf 2019 10 21 86...
Page 100: ...Operating instructions Summary 4812159201_F pdf 2019 10 21 88...
Page 102: ...Preventive maintenance 4812159201_F pdf 2019 10 21 90...
Page 106: ...Maintenance Lubricants and symbols 4812159201_F pdf 2019 10 21 94...
Page 118: ...Maintenance 10h 4812159201_F pdf 2019 10 21 106...
Page 124: ...Maintenance 50h 4812159201_F pdf 2019 10 21 112...
Page 140: ...Maintenance measures 500 h 4812159201_F pdf 2019 10 21 128...
Page 152: ...Maintenance 1000h 4812159201_F pdf 2019 10 21 140...
Page 167: ......
Page 168: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...